Part Number 3085006.001, Rev. A
3
TESTING THE LOCK
1.
TEST the lock with a known good credential to confirm
it will open as desired when installed.
a.
REMOVE the cover from the lock body.
b.
PASS the wire and shaft from the reader through
the lock body.
NOTE:
The wire connector is keyed.
c.
CONNECT the wire connector from the reader to
the socket in the lock compartment.
d.
CONNECT the 10-position Molex Micro-Fit 3.0 cable
between the K200 and the EAC, and ENSURE power is
ON.
e.
PRESENT a credential known to the EAC.
f.
WHEN
a green LED indicates access is granted,
THEN
TWIST the knob to retract the latch.
g.
Carefully UNPLUG the cable, and SEPARATE the
lock and reader to prepare for installation.