20
-
Figure 2.9 Connecting Box (Back)
Port #
Port Name
Description
d
Trigger Port
Outputs external trigger signals for multi-sensor synchronization.
Connector (socket): Molex, LLC 5023520300
Recommended wire connector (plug): Molex, LLC 5023510300
Voltage: 0 to 3.3 V
Signal type: pulse
Max. current output level: 12 mA
Pin Description for the trigger port:
Pin #
Direction
Pin Description
1
Input
GND, to ground the external trigger signal
2
Output-Encoder
Trigger signal: outputs one pulse when the LiDAR rotates 0.05°
Pulse width: 8.31 μs @ 600 RPM, 4.17 μs @ 1200 RPM
3
Output-Index
Trigger signal: outputs one pulse when Channel 42 passes the LiDAR's 180° position (see Figure 1.4)
Pulse width: 2.87 μs @ 600 RPM, 1.44 μs @ 1200 RPM
Summary of Contents for Pandar128E3X
Page 1: ...www hesaitech com HESAI Wechat Pandar128E3X 128 Channel Mechanical LiDAR User Manual...
Page 11: ...9 2 Setup 2 1 Mechanical Installation Figure 2 1 Front View Unit mm...
Page 12: ...10 Figure 2 2 Bottom View Unit mm...
Page 13: ...11 Quick Installation Figure 2 3 Quick Installation...
Page 14: ...12 Stable Installation Figure 2 4 Stable Installation...
Page 57: ...55 4 6 Monitor The LiDAR s input current voltage and power consumption are displayed...
Page 60: ...58 4 9 Security Cyber Security Master Switch OFF Cyber Security Master Switch ON...
Page 70: ...68 In case the following warnings appear select Trust this CA to identify websites...