53
-
4.4
High Resolution
The horizontal resolution of far field measurement is configurable on-the-fly.
Configuration Mode
Frame Rate
Horizontal Resolution of Far Field Measurement
Standard
10 Hz
0.2° for all channels
20 Hz
0.4° for all channels
High Resolution
10 Hz
0.1° for the 64 high-res channels (Channel 26 to Channel 89)
0.2° for the other channels
NOTE Channel # counts from 1 to 128
20 Hz
0.2° for the 64 high-res channels (Channel 26 to Channel 89)
0.4° for the other channels
NOTE The horizontal resolution of near field measurement is always 0.4° at 10 Hz and 0.8° at 20 Hz. See Appendix I (Channel Distribution) for
the definition of near/far field measurement.