6
-
1.3
Channel Distribution
The vertical resolution is
· 0.125° from Channel 26 to Channel 90
· 0.5° from Channel 2 to Channel 26, as well as from Channel 90 to Channel 127
· 1° between Channel 1 and Channel 2, as well as between Channel 127 and Channel 128
· detailed in Appendix I (Channel Distribution)
Figure 1.5 Channel Vertical Distribution
Figure 1.6 Laser Firing Position (Unit: mm)
Each channel has an intrinsic angle offset, both horizontally and vertically.
The offsetted angles are recorded in this LiDAR unit's angle correction file, which is provided when shipping the unit.
In case you need to obtain the file again:
· Send this TCP command
PTC_COMMAND_GET_LIDAR_CALIBRATION
, as described in Hesai TCP API Protocol (Chapter 6).
· Or contact a sales representative or technical support engineer from Hesai.
Summary of Contents for Pandar128E3X
Page 1: ...www hesaitech com HESAI Wechat Pandar128E3X 128 Channel Mechanical LiDAR User Manual...
Page 11: ...9 2 Setup 2 1 Mechanical Installation Figure 2 1 Front View Unit mm...
Page 12: ...10 Figure 2 2 Bottom View Unit mm...
Page 13: ...11 Quick Installation Figure 2 3 Quick Installation...
Page 14: ...12 Stable Installation Figure 2 4 Stable Installation...
Page 57: ...55 4 6 Monitor The LiDAR s input current voltage and power consumption are displayed...
Page 60: ...58 4 9 Security Cyber Security Master Switch OFF Cyber Security Master Switch ON...
Page 70: ...68 In case the following warnings appear select Trust this CA to identify websites...