©2017 Hestan Commercial Corporation
28
EN
TROUBLESHOOTING GUIDE
Symptom
Check
Burner will not light
Gas supply not on / shutoff valve closed
LP gas cylinder empty
Power cord not plugged in, or no power to receptacle, or blown fuse
Low gas pressure to unit
Burner ports near igniter are obstructed or dirty
Burner not installed correctly on orifice
Defective or clogged burner valve
Incorrect orifice or clogged orifice
Igniter defective (not glowing)
Defective regulator or regulator installed improperly
Burner will not stay lit
Burner ports obstructed or dirty
Vent plugged on regulator or regulator installed improperly
Windy conditions
Low gas pressure
Slow to heat up
Low gas pressure or low LP cylinder
Burner ports are obstructed or dirty
Defective or clogged burner valve
Incorrect orifice or clogged orifice
Gas Odor
Burner went out or did not light
Loose or broken gas line
Ruptured pressure regulator
Burner not installed correctly on orifice
Poor combustion, air-fuel mixture not adjusted properly
Obstructed/dirty burner ports
Burner not working well / lazy
or yellow flame
Burner ports are obstructed or dirty, check for spider webs
Poor combustion, air-fuel mixture not adjusted properly
Gas pressure incorrect / incorrect regulator
Orifice sized incorrectly for gas type
Rotisserie will not light or will
not stay lit
Not holding in the control knob long enough
Windy conditions
Igniter defective (not glowing)
Power cord not plugged in, or no power to receptacle
Interior halogen lights not
working
Power cord not plugged in, or no power to receptacle
Check for burned-out bulb
Control panel LED lights not
working
Power cord not plugged in, or no power to receptacle
Check fuse on electrical box.
Rotisserie motor not working
Power cord not plugged in, or no power to receptacle
Summary of Contents for Aspire EAB30LPBU
Page 2: ......
Page 13: ... 2017 Hestan Commercial Corporation 11 EN INSTALLATION continued ...
Page 38: ...THIS PAGE LEFT INTENTIONALLY BLANK ...
Page 47: ......