3.1. Liability
By providing these instructions, Heta A/S dis-
claims all liability, both personal and statutory,
for any accidents that may arise due to failure
– either fully or in part – to observe the instruc-
tions enclosed herein.
Heta A/S disclaims all liability in relation to in-
correct use of the stove, abnormal usage by
the customer, unauthorised replacement and/
or repair, or the use of non-original spare parts
for this model
The manufacturer disclaims all liability, both
personal and statutory, direct and indirect, at-
tributable to:
•
Inadequate maintenance
•
Failure to observe the instructions in this
manual
•
Failure to observe safety directions
•
Irregular installation with failure to ob
serve applicable standards in the
destination country
•
Installation carried out by unqualified or
untrained personnel
•
Replacement or repair not authorised by
the manufacturer
•
Use of non-original spare parts
•
Extraordinary events
3.2. Spare parts
Use only original spare parts.
If you have any questions concerning your
pellet stove, Heta strongly recommends that
you contact your dealer immediately.
3.
The pressure sensor measures whether there
is sufficient draught in the chimney. If problems
with inadequate draft or a blocked chimney
arise, the pressostat shuts down the stove.
(press the reset button to reactivate the stove)
1.
Thermal protection shuts down the stove if
the temperature in the wood pellet tank be-
comes too high (85°C).
3.3 Safety systems
Greenfire pellet stoves are equipped with ad-
vanced safety systems to prevent damage
to the stove or residential environment which
could arise due to a fault in the appliance or
inadequate maintenance, chimney draught, etc.
If a fault occurs, pellet feeding ceases and
the stove shuts down automatically.
The stove has the following three safety sy-
stems:
2.
The thermal sensor in the pellet tank activa-
tes at 82°C and automatically reduces
the heat level. If this fails to achieve a drop in
temperature, the thermal protection (1) is acti-
vated