5
energy source, you save the environment about
1.3 kg CO
2
every time you have used 1 kg nor-
mal wood.
Chimney fires
In the event of a chimney fire – which often re-
sults from incorrect operation or protracted fi-
ring with moist wood – close the door and shut
off the secondary/start-up air supply to smother
the fire. Call the fire department.
airflow regulation
The combustion air flow is controlled by the
handle at the top right, as shown on fig. 1.
The combustion air flow is fully open when the
handle is as far back as possible. Combustion
air is gradually reduced by moving the handle
forward, and is completely shut off when it rea-
ches the front position.
Before commencing, it is very important to en-
sure the aeration vent (Fig. 2) in the oven is clo-
sed, as shown in Fig. 3.
lighting the stove
Place two pieces of wood on the bottom. Stack
kindling on top in layers with air between. Set-
ting fire starter (bag, brick, paraffin) on the top,
now you are ready to light the fuel. The flames
must work from the top down.
The use of lighter fluid, oils or
any liquid fuels is strictly forbid-
den from use in a wood stove.
Fully open the combustion air and leave the
door ajar (about 1 cm open).
Once the fire is established and the chimney is
hot (after about 3-5 minutes) closed door and
regulate the air into operating position. We re-
commend, all of the first fuel is burned with the
combustion air fully open in the operating po-
sition. This ensures the stove and chimney are
thoroughly heated.
Startup/Lighting
Scan the code and select a
language.
adding fuel
A fresh supply of fuel should normally be added
while there is still a good layer of hot embers.
Spread the embers over the base grate, most
towards the front of the stove. Lay a single layer
of wood fuel corresponding to about 1.5 kg over
the embers, at right angles to the stove door.
Turn handle into top position (max. Combusti-
on- airflow). Keep door ajar if necessary. (The
door should not be left open but fuel will ignite
more quickly while the door is ajar.) The wood
should ignite within a very short time (usually
1-3 minutes). If the door is ajar, close it as soon
as the fuel is ignited. When the flames spread
across the fuel stack, adjust the combustion air-
flow to the required level. Nominal operation 6,8
kW corresponds to 80% combustion airflow.
When adding fuel, make sure that the fuel is not
too tightly packed, as this will lead to poorer
combustion and fuel inefficiency.
4
1
Open
Closed
2
3
Closed
Closed