background image

With your new wood stove you should find the following: 

Betjenings- og 

opstillingsvejlednin

g

dansk design  .  dansk

 kvalitet  .  dansk pro

duktion

www.heta.dk

dk

scan-line 80 og 80 Xl

Operating /
Instruction manual

Heta glove

Q.C. check 

Data plate

Heta A/S

Jupitervej 22 . DK-7620 Lemvig . Denmark

EN 13240:2001/A2:2004 - AEA - NS 3058/3059, Aus §15A

Testrapport: 300-ELAB-2276-EN

SN No. 

07-2017

Scan-Line 1000

Brændsel 

Træ

Ovnen er godkendt til intermitterende brug
Følg fabrikantens brugervejledning
Ovnen kan anvendes på røggassamleledning

Afstand til brændbart - bag ovn 

120 mm

Afstand til brændbart - foran af ovn 

1300 mm

Afstand til brændbart - side af ovn 

425 mm

Afstand til brændbart - under ovn 

---- mm 

Nominel ydelse / rum opvarmningsudelse 

7,7 kW

Middel CO emission i mg/Nm

3

  

960 mg/Nm

3

 

Middel CO emission 

0,077% 

Røggas temperatur  

204

C

Støv 

10 mg/Nm

3

Virkningsgrad 

86%

NOx 

80 mg/Nm

3

OGC 

76 mgC/Nm

3

DOP-Scan-Line 1000 2017

8057 0000-DK

Congratulations on your new stove. We are sure that you will be happy with your investment, espe-
cially if you follow the advice and instructions we have put together in these operating instructions.

Scan-Line 800 combustion chamber, and are therefore approved, like the Scan-Line 800, under EN 
13240, DINplus, 15 a B-VG and NS 3058/3059. Approval means that consumers can be sure, that 
the stove meets a range of specifications and requirements intended to ensure that the materials 
used are of good quality, that the stove does not adversely affect the environment, and hat it is 
economical to use.

Heta A/S

Jupitervej 22, 
DK-7620 Lemvig
Phone: +45 9663 0600
E-mail: heta@heta.dk

Copyright © 2014 
Heta is a registered 
trademark of Heta A/S

05.02.2021
0037-1415 Version 1,2

Printed in Denmark
Subject to printing errors 
and changes.

required tools are not supplied.

Summary of Contents for SCAN-LINE 80

Page 1: ...tinG anD installation instrUCtions Danish design Danish Quality Danish Production www heta dk EN Scan line 80 and 80 XL APPROVED FOR USE IN SMOKE CONTROL AREAS WHEN BURNING DRY WOOD LOGS OR AUTHORISED...

Page 2: ...0 077 R ggas temperatur 204o C St v 10 mg Nm3 Virkningsgrad 86 NOx 80 mg Nm3 OGC 76 mgC Nm3 DOP Scan Line 1000 2017 8057 0000 DK Congratulations on your new stove We are sure that you will be happy w...

Page 3: ...low national and local regulations However the area of the ope ning should never be less than 175 cm2 which corresponds to a diameter of 150 mm If a dam per is fitted in the flue gas pipe there must a...

Page 4: ...d pressure impregna ted wood or chipboard as these materials can emit poisonous fumes and smoke Correct fi ring using well seasoned wood provides opti mal heat output and maximum economy At the same t...

Page 5: ...ully open in the operating po sition This ensures the stove and chimney are thoroughly heated Startup Lighting Scan the code and select a language Adding fuel A fresh supply of fuel should normally be...

Page 6: ...es of gas and this gas can explode if the intake of primary and se condary air is insufficient It is an advantage always to leave some ash lying in the bottom of the combstion chamber Take care when e...

Page 7: ...r example using wet wood can result in the viewing window becoming co vered in soot This soot can be easily and effec tively removed by using proprietary stove glass cleaner Cleaning and repairing soa...

Page 8: ...mm hose is recommended available from Heta which can handle tempe ratures up to 200 C Fig 1 illustrates the two options downwards or backwards 2 3 4 5 Emptying the ash pan The ash pan is located behi...

Page 9: ...ea to remove the two heat storage stones before making the change After swapping the flue outlet connector and blanking plate the stove is ready for rear flue connection Swap the flue outlet connec to...

Page 10: ...he top in line with the installation instructions for soapstone ceramic Scan Line 80 and 80XL stoves on page 11 19 The dimensions on the drawing fig 1 have been measured from the bottom edge of the ba...

Page 11: ...est to change this before installing the cladding See the operating instructions at page 9 Before commencing installation ensure that the stove is level Varenr soapstone Antal SL 80 Antal SL 80XL A 00...

Page 12: ...8 14 F 0023 2369 2 G 0023 2370 2 2 E E E E E E E C D Side 23 27 11 2015 G G A F F CLADDING TYPE AND PRODUCT NUMBERS Mounting of radiant plates Scan Line 80 with ceramic 1 2 4 3 IMPORTANT Before using...

Page 13: ...he mounting pegs 47 mm from the top of the cladding stone in the large circular holes in the keyholes Let the stone slide down so the pegs are at the bottom of the keyholes When installing soapstone p...

Page 14: ...14...

Page 15: ...however you want as the same type of clad ding stone panels are used on the opposite side of the stove D C E E E E E E E Fourteen cladding stone panels E are needed for the Scan Line 80 XL These pane...

Page 16: ...s may need to be adjusted to be level with the cladding stones on the sides of the stove Do this by loosening the four screws two on each side use a 4 mm hex key Start by loosening the bottom two scre...

Page 17: ...the cladding stones have been installed Cover plate 4027 0039 is not used if the rear flue outlet is being used Cover plate 4027 0037 is not used if the out side air connection is being used If there...

Page 18: ...mastones The other two can be purchased as optional extras Remove the transportation bracket before using the stove or installing additional ther mastones The Scan Line 80 has no therma stones Screw t...

Page 19: ...flue outlet is being used remove the centre cover plate using pliers X Y Z INSTALLATION OF CERAMIC TOP AND CONVECTION TOP PANEL Install the convection top panel as follows 1 push x into the slot y in...

Page 20: ...s used to burn solid fuel in those areas other than authorised fuels have been exempted by an Order made and sig ned by the Secretary of State or Minister in the devolved administrations The Scan Line...

Reviews: