CHANGING THE BATTERY

The battery voltage is monitored continuously by the 
transmitter.

When the battery is nearly discharged, the LED on the 
transmitter will blink red/yellow, although the LED will 
continue to blink green with every transmission.

 

When 

the batteries are low, they need to be changed 
immediately.

1. Position the crane/machine into a safe place or 

safe condition within a set amount of time after a 
visual notice is given. This time setting is 
programmable under the "Low Voltage" option in 
the H-Link software. Refer to the HH-MFSHL 
H-Link Programming Manual.

2. Press the E-stop pushbutton.

3. Remove the discharged batteries.

4. Insert new batteries. 

NOTE: 

Commercially available rechargeable batteries 

may be used.

5. Follow "Start-up Procedure" to begin operation.

BATTERY DISPOSAL

IMPORTANT: 

AVOID ENVIRONMENTAL 

POLLUTION. Electronic equipment and components 
are considered to be hazardous waste. Discarded 
batteries are hazardous waste and must not be 
disposed of with typical refuse. Contact a professional 
hazardous waste disposal service.

MAINTENANCE

WARNING: 

The transmitter will switch to the 

EMERGENCY STOP condition after the set 
amount of time expires.

Lever

Battery Compartment

Alkaline Batteries

Alkaline Batteries:

1. Press the lever at the black end of the battery 

tube downwards to release the battery tube from 
the battery compartment.

2. Remove the two discharged alkaline batteries.

3. Insert two new 1.5V alkaline batteries into the 

battery tube with the negative pole first, as shown 
on the battery compartment.

IMPORTANT: 

Be sure that you only use alkaline 

batteries. 

4. Insert the battery tube into the transmitter’s 

battery compartment with the open end first (it will 
help to hold the tube vertically to prevent the 
batteries from falling out).

5. Press the battery tube into the battery 

compartment until it fully locks into place.

Battery Tube

WARNING: 

EXPLOSIVE GASES AND 

FLYING DEBRIS can cause death or serious 
injury. Use of unauthorized replacement 
batteries could cause a battery explosion, 
resulting in injury or death of the operator or 
other people in the work area.

PRELIMINAR

Y COPY

Summary of Contents for HH-L-MFSHL TS7P

Page 1: ...r Avenue Halton Hills Ontario L7G 4X4 1 800 816 4459 Fax 1 905 702 0501 2005 Hetronic Inc All rights reserved No part of this publication may be reproduced transmitted transcribed stored in a retrieva...

Page 2: ...er 6 Receiver Housing 7 External Antenna Installation 7 Standard Antenna Extension 7 Top Mount Antenna Extension 7 Connect Electrical Wiring 8 Quick Disconnect Plug 8 Quick Disconnect Plug Wire Termin...

Page 3: ...arising out of the use of unauthorized replacement parts BEFORE ATTEMPTING TO OPERATE THIS SYSTEM 1 Make sure all installation has been properly completed 2 Understand all safety precautions provided...

Page 4: ...ess code This code allows the operation of multiple systems in the same general vicinity The receiver only accepts commands from the transmitter with the same address code MFS Transmission Technology...

Page 5: ...pment PRACTICES AND LAWS Practice usual and customary safe working precautions for the benefit of yourself and others Understand and follow all safety messages Be alert to unsafe conditions and the po...

Page 6: ...e gases or liquids Receiver must be protected from ambient temperatures outside the range of 18 to 158 F 25 to 75 C Receiver Production Number Locate the Hetronic Production number decal on the receiv...

Page 7: ...g 4 Insert the mounting screws through the holes in the housing block and tighten into the mounting surface 5 Bundle any excess antenna cable and secure with tie wraps or equivalent IMPORTANT DO NOT r...

Page 8: ...system using the new H Link wireless technology These are preset at the factory and are password protected Refer to the HH MFSHL H Link Programming Manual for more details IMPORTANT The Address and F...

Page 9: ...P DK9 S0 S t o p S t o p DK1 DK2 DK3 DK4 DK5 DK6 DK7 DK8 DK9 DK10 DK11 DK12 DK13 DK14 S1 S2 S3 S4 S5 S6 S7 HH L MFSHL TS7P S t o p S t o p S0 TEST PROCEDURES WARNING FAILURE TO FOLLOW INSTRUCTIONS cou...

Page 10: ...cates that the E Stop contact is open crane machine motions will NOT operate The LED on the receiver should flash yellow 5 Activate the motion toggle switches There should be NO movement of the crane...

Page 11: ...that the transmitter batteries are fully charged and inserted into the transmitter handle If any control is NOT in the Off neutral position when the battery is inserted the transmitter will not turn...

Page 12: ...a switch is active when the batteries are inserted the unit will go into an error state The red LED will come on and stay on until the active switch is turned off LED DESCRIPTION Transmit Mode Green...

Page 13: ...sposed of with typical refuse Contact a professional hazardous waste disposal service MAINTENANCE WARNING The transmitter will switch to the EMERGENCY STOP condition after the set amount of time expir...

Page 14: ...fter normal start up procedure E Stop switch engaged Pull out E Stop switch Batteries fully discharged Check batteries to ensure a full charge Replace with new batteries if necessary No power to the r...

Page 15: ...AA batteries Operation time Up to 500 hours Functions E Stop pushbutton 6 motion toggle switches Proportional grey code trigger switch Antenna Internal HH L MFSHL TS7P TRANSMITTER Weight 1 3 lbs 590g...

Page 16: ...operator is responsible for understanding and following all safety precautions in this and other applicable operator manuals INSTALLATION AND SAFETY TEST DATA Crane machine Data Manufacturer Model Num...

Page 17: ...the crane machine controls Maintained control The function activates when the control is placed in the ON position The function stops when the control is placed in the OFF position Momentary control T...

Page 18: ...c Millisecond MHz Megahertz MOV Metal Oxide Varistor type of surge suppressor mW Milliwatt NiCd Nickel Cadmium NiMH Nickel Metal Hydride PLC Programmable logic controller PLL Phased locked loop PTO Pr...

Page 19: ...any Company supplied items or materials List prices or discounts are subject to change without notice Quoted prices will be honored for a period of 90 days from the date of the written quotation unles...

Reviews: