background image

Hetronic

 

www.hetronic.

nl

BATTERY CHARGING SYSTEM

The Hetronic UCH-2 is a new and improved battery 

charging system. It includes upgraded features to better 

charge and troubleshoot the battery.
Battery and charger contacts are gold-plated and self-

cleaning to ensure positive connection. The battery and 

charger contacts are mechanically cleaned each time the 

battery is removed from or inserted into the battery 

compartment.

Features

Normal charge or Fast charge

 of Hetronic standard

batteries

Trickle charge

 - After charging process is complete,

battery can remain in charger without being damaged 

by over-charge.

Battery diagnostics

 - Charger determines if battery

is damaged.

Gold plated contacts

 ensure clean, positive contact

between battery and charger.

LED status lights

 indicate charging process as well

as battery diagnostics

The Battery Charger

One battery charger is designed for 115/230 VAC and plugs 

into a typical wall outlet. Another charger is designed for 

12/24 VDC and is wired into the constant crane/machine 

power source.
When the battery is inserted into the charger, a flashing 

“CHARGE” LED lights. The charge process is terminated 

by detecting peak battery voltage or after 5 hours and the 

“READY” light goes on. When the “READY” light is lit, the 

charger continues to "trickle" charge the battery.

NOTE: 

If the battery is bad and has an open cell, no LEDs 

will light up. If the battery has a shorted cell, the “CHARGE” 

LED will blink continuously after ca. 10 minutes. In either 

case, the battery must not be used. Properly dispose of the 

bad battery.

Battery Charger Technical Specifications

LED Description

CHARGE LED

READY LED

FAST
CHARGE
Button

CHARGE LED

FAST

Battery

Charging current

Normal: 300 mA
Fast charge: 780 mA

Charge time 
(Standard Hetronic 
1200 mAh battery)

Normal: approx. 4 hours
Fast charge: less than 2 hours (no 
damage to battery, or negative effect 
to duty cycles)

Temperature range

-20C to +75C

Power supply

DC - 12-24 VDC, polarity protected
AC - 110-220 VAC, US/Japan or EU 
plug

Yellow CHARGE 

LED

Lights constantly - Charging
Continuous flashing - Damaged 

battery cell (short)

Red FAST 

CHARGE LED

On - Fast charge in process

Green READY 

LED

On - Battery fully charged, trickle 
mode in process

No LED on after 

battery inserted

Damaged battery cell (open cell)

Yellow LED

Red LED

Green LED

Technical Information

Battery Charger UCH-2 3.6V

SALS_018.2_UCH-2/3.6

January 2004

Page 1 of 2

Reviews: