6
NOTICE ON THE LABELLING AND COLLECTION OF WASTE ELECTRONIC EQUIPMENT
This symbol on the product or its packaging requires separate collection of waste electrical and electronic equipment (WEEE). It means
that this product should not be disposed of with other household waste. Proper disposal of WEEE helps to avoid potential harm to the
environment and human health.
The mandatory selective collection of WEEE is the liability of the user, who should hand over WEEE to a WEEE collection plant.
ź
ź
This equipment is not intended to be operated by individuals (including children) with reduced physical,
sensory or mental capabilities or lack of experience and knowledge of the equipment, unless they have been
given supervision or instruction concerning the use of the equipment by individuals responsible for their
safety. Children should be supervised to ensure that they do not play with the equipment.
If the integrated power cord is damaged, have it replaced by the manufacturer, a professional repair service, or
a qualified professional to avoid hazards.
CAUTION!
Scan this code to download the
latest technical documentation:
RES installation
type
Unit type
Controller access
password
PV installation
MONO & SPLIT
heat pumps
DHW heat pumps
(without a DHW tank)
DHW heat pumps
(with a DHW tank)
Solar thermal system
Extension modules
LIST OF SUPPORTED CONTROLLERS
5
Controller model
RS485 port settings
OPTI-ENER
PCCO SPLIT 6kW
PCCO SPLIT 10kW
PCCO SPLIT 13kW
PCCO SPLIT 20kW
PCWU 2,5kW
PCWU 3,0kW
PCWU 200K-2,3kW
PCWU 300K-2,3kW
PCWU 300SK-2,3kW
PCWU 200eK-2,5kW
PCWU 300eK-2,5kW
ZSP 18
ZSP 18E
ZSP 28-01 ECO
COP protection module
P01
P02
G-426-P02
G-426-P01
G-426-P01
G422-P06;
G422-P07
G422-P08
G422-P09
G422-P09a
GH26-P09
GH26-P09A
G439
G922
-
1305
1305
1305
0110
-
-
Baud rate:
38400
-
Logical address
: 2
-
Physical address
: 3
-
Baud rate:
38400
-
Logical address
: 2
-
Physical address
: 4
-
Baud rate:
38400
-
Logical address
: 2
-
Physical address
: 5
-
Baud rate:
38400
-
Logical address
: 2
-
Physical address
: 6
-
Baud rate:
38400
-
Logical address
: 2
-
Physical address
:
7(G422)
8(GH26)
9(G439)
-
Baud rate:
38400
-
Logical address
: 2
-
Physical address
: 11
Depending on the type of installation and the controller model, different settings must be made for the RS-485 port which handles the
communication with the EKO-LAN modem. The list of devices compatible with the modem and the required settings are shown in Table 2.
If you modify the port settings, restart the managed unit (the controller) by cycling its power supply and turning the unit on again. Next,
wait 2 minutes after turning on the unit and check the LED indicators on the EKO-LAN modem by comparing their statuses to Section 3.3.
Tab.2
RS485 port settings for Hewalex units
7 /03.2020