97
•
Switch C, Switch D, and Switch E detect congestion for traffic with 802.1p priority 5.
•
Switch D and Switch E do not detect congestion for traffic with 802.1p priority 1.
Figure 37 Network diagram
Configuration procedure
1.
Configure Switch A:
# Create VLAN 100, and assign Ten-GigabitEthernet 1/0/1 to the VLAN.
<SwitchA> system-view
[SwitchA] vlan 100
[SwitchA-vlan100] port ten-gigabitethernet 1/0/1
[SwitchA-vlan100] quit
# Configure Ten-GigabitEthernet 1/0/2 as a trunk port, and assign it to VLAN 100.
[SwitchA] interface ten-gigabitethernet 1/0/2
[SwitchA-Ten-GigabitEthernet1/0/2] port link-type trunk
[SwitchA-Ten-GigabitEthernet1/0/2] port trunk permit vlan 100
[SwitchA-Ten-GigabitEthernet1/0/2] quit
# Enable LLDP globally.
[SwitchA] lldp global enable
# Enable CN TLV advertising on Ten-GigabitEthernet 1/0/1.
[SwitchA] interface ten-gigabitethernet 1/0/1
[SwitchA-Ten-GigabitEthernet1/0/1] lldp tlv-enable dot1-tlv congestion-notification
[SwitchA-Ten-GigabitEthernet1/0/1] quit
# Enable CN TLV advertising on Ten-GigabitEthernet 1/0/2.
[SwitchA] interface ten-gigabitethernet 1/0/2
[SwitchA-Ten-GigabitEthernet1/0/2] lldp tlv-enable dot1-tlv congestion-notification
[SwitchA-Ten-GigabitEthernet1/0/2] quit
# Enable QCN.
[SwitchA] qcn enable
# Assign the switch to the CND with CNPV 1, and configure all interfaces to negotiate the
defense mode and alternate priority by using LLDP.
[SwitchA] qcn priority 1 auto
Switch A
Switch B
Switch C
RP 1
RP 2
CND 1
Switch E
RP 4
CND 2
Switch D
RP 3
XGE1/0/1
XGE1/0/1
XGE1/0/1
XGE1/0/1
XGE1/0/2
XGE1/0/2
XGE1/0/2
XGE1/0/2
XGE1/0/1
XGE1/0/2
XGE1/0/4
XGE1/0/3