Sensitivity (in meters)
Specifies the offset required for a LED in the light bar to light up. This value is associated with the five LEDs in
the center of the light bar. For the other LEDs, the on-board computer divides the rest of the stride width
among each LED. To increase sensitivity, decrease the spacing and to decrease sensitivity, increase the
spacing. Example: to enter a 15 centimeter sensitivity, enter 0.15.
Figure - Lightbar sensitivity
·
Lateral overlap (in meters)
Overlap the application (reassemble). Used mainly in sprayer implements.
Figure - Lateral overlap
·
Activity overlap (Yes or No)
Reapplies to an already treated area, overlapping the activity on the application map. For example, if an
implement passes over an area where it has already been applied, it does not shut off and continues
application normally, thus overlapping application in that area.
·
Overlap rate (in %)
The
Overlap rate
parameter is only enabled when the
Activity overlap
is set to
No
. Insert the overlap
percentage needed for the application or a section shuts off automatically. For example, if the overlap rate is
adjusted at 50% and the section has a 4-meter length, when 2m of overlap are reached, the implement will
shut off. The
Overlap rate
is calculated based on the implement width.
Figure - Overlap rate
Important
The
Overlap rate
parameter must be set even if
No
is selected for the overlap, because there
is an acceptable rate that the implement cannot avoid so that it can detect that it is over an