Operation
TP-R-400
22
2.2.2.2
Mounting tool holders Ø28
1. Dismounting the tool holder:
1.1
Remove clamping screws from the tool holder.
1.2
Remove tool holder.
1.3
Remove all "A" and "C" screws from the modular adapter (refer to Fig. 9).
1.4
Remove modular adapter from touch probe.
2. Mounting the tool holder:
2.1
Carefully slide the modular adapter onto the probe body. Align the „C“ threads with the conical bores.
2.2
Insert both clamping screws „C“ and tighten lightly.
2.3
Insert adjustment screws „A“ and tighten lightly.
2.4
Slide the tool holder onto the modular adapter.
2.5
Insert the clamping screws and tighten to the torque specified in Fig. 9.
3. Align the stylus to spindle center (refer to chapter 2.2.5).
4. Calibrate the touch probe.
Mounting/dismounting the tool holder
C = Clamping screw
M5x0.5x7 (AF2.5 mm)
(2x)
(1351)
Hexagon key
AF2 mm (1097)
AF2.5 mm (1346)
SW4 mm (3489)
A = Adjustment screw M4x8
(AF2 mm) (4x)
(1352)
Touch probe
Tool holder
Clamping screw
M10x1x11 (AF4 mm) (2x)
(0506)
M=10 Nm (7 lbf.ft)
Modular adapter (D20-MO-B)