TP-R-400
Operation
25
To access the touch probe menu, press the button on the back of the touch probe for approx. 2 s. Then press the
button twice to confirm menu call-up. The display then shows some brief operating information and after approx. 5 s
automatically opens the main menu, which consists of 5 setting levels (submenus). The following table lists these
submenus with a brief description of each function.
Setting level/Submenu
Description
Setup
The
"Setup"
submenu contains all the necessary settings for setting up the
touch probe and for pairing with a corresponding radio-wave receiver. The
following settings can be made here individually:
•
Mode:
Define whether the device is to be used
as a touch probe or as a tool setter
•
Channel:
Define the receiver channel to be used
for transmission
(only when using RWR95.51)
•
Activation Code:
Define the activation codes for the
touch probe
•
Safety:
Define the interference safety level
•
Receiver Serial:
Enter the serial number of the radio-wave receiver
to be paired
Info
The
"Info"
submenu is used to display all information on the settings, power
and firmware version of the touch probe. The following information can be
called up here individually:
•
Settings:
Display the settings defined in the
"Setup"
menu
•
Version:
Display the firmware version of the touch probe
•
Radio Strength:
Display the strength of the received radio-wave
signal from the receiver
•
Legal Info:
Display regional radio license information
Set PIN
The
"Set PIN"
submenu is used to set, change and delete a lock password
(PIN). This function can be used to protect the touch probe settings against
unwanted access.
Save/Load
The
"Save/Load"
submenu can be used to save the current touch probe
settings and to load them at a later time. For this purpose,
3 internal memory
slots
are available in the touch probe memory. Loading previously saved
settings will overwrite the currently active settings.
Manual Mode
The
"Manual Mode"
submenu can be used to activate a manual touch probe
mode in which the touch probe responds to stylus deflections by blinking
orange with the integrated LED ring. In this mode, the connection to the
receiver is disconnected and no status signals are transmitted to the control.
2.2.4.2
Operating the menu
To start the touch probe menu, it must be in"Sleep Mode" (e.g. Immediately after inserting the battery).
The menu is operated via only one button on the back of the touch probe (see also Fig. 12).
The following operating options are available:
•
Press and hold the button (approx. 2 s):
Start/Exit the menu/submenu (Back)
•
Briefly tap the button:
Scroll through a menu/submenu
•
Tap the button twice:
Select the menu item or open the submenu