Number of
Component
Details
Hardware
• +/- 5% Voltage margin control on
5V and 12V rails
• Trouble history implementation
• 5v and 12v DC output at 1650W
4 (2 in each
PSU)
Fans
• N+1 redundant cooling
• any one fan can fail and the
system will continue to operate
1.2
Specification Summary
The following table is a summary of specs relevant and represent a fully configured enclosure:
Table 2: Specification Summary
Operating
Non-operating
Condition (Fully Configured)
5°C to 35°C
-30°C to 60°C
Temperature
20°C per hour
5°C per hour
Temperature Gradient
1°C per 125m above 950m
1°C per 300m above 3000m
Temperature De-rating
8% to 80% non-condensing
8% to 80% non-condensing
Relative Humidity
30% per hour maximum
30% per hour maximum
Relative Humidity Gradient
-300m to 3,048m
984 ft. to 10,000 ft.
-300m to 12,000m
-984 ft. to 39,370 ft.
Altitude
3.5g 6ms Pulse vertical shock
8g 6ms Trapezoidal
Shock
Random 0.25 Grms, 5-10Hz
0.05 g sine wave sweep,
10-300Hz
Random 0.6 Grms 10-300Hz
Vibration
Typical: 1.0 KVA
N/A
Power Requirements
Max: 1.8 KVA
Maximum Enclosure Weight (full configuration—HDD): 207.6
lbs./93.71 kg
Minimum Enclosure Weight (without drives): 99.6 lbs./45 kg
Weight
Dimensions (Enclosure): 174.8mm x 424mm x 871.2mm/6.88in. x
16.69in. x 34.3in.
System Dimensions
Dimensions (with CMAs): 174.8mm x 424mm x 1100mm/6.88in. x
16.69in. x 43.3in.
8
1
Document Summary
User Guide
1.2
Specification Summary