background image

Designed and Engineered in the UK by HH Electronics LTD. 

© 2022 HH Electronics Ltd

ACTIVE STAGE MONITOR

LIVE SOUND

Model

TRM-1201

System Type

12" Active Powered Stage Monitor, Bass Reflex

Frequency Response

1

50Hz - 20KHz (-10dB) (FOH mode)

55Hz - 18KHz (-3dB)

LF Driver

12-inch HH Driver

HF Driver

1 inch HH Compression Driver 

Max SPL 1m

2

130 dB SPL

Coverage Angle

80° x 80°

Crossover Frequency

2.8KHz

Amplifier

Power Rating

350W RMS, 700W Continuous, 1400W Peak

Limiter

Dual Band Limiters

Input Connector

Balanced Female XLR/6.3mm Jack Combi Socket

Output Connector

Balanced Male XLR with ground lift switch

Signal Indicators

Power, Signal Present, Clip Indicator

Controls

Volume, Monitor/FOH mode

AC Power

100V-120V~/220-240V~+ 50/60Hz User Switchable

AC Power Consumption

300W

AC Power Inlet

IEC C14 INLET

Enclosure

Cabinet

Acoustically optimised Plywood cabinet with integrated carry handles

Finish

Painted Black 

Monitor Angle

35°

Pole Mount

35mm Pole Mount Socket Included

Grille

Rear reinforced heavy gauge steel grille with acoustic foam

Unit dimensions (HWD)

340 x 510 x 500mm,  13.4" x 20.1" x 19.7"

Unit weight

17.7Kg, 39 lbs

Carton dimensions (HWD)

605 x 540 x 470mm,  23.8" x 21.3" x 18.5" , 0.154 M3

Packed weight

21Kg, 46.3 lbs

EAN13

5060109457582

In the interest of continued development, HH reserves the right to amend product specification without prior notification.

DIMENSIONS (in mm)

1  Measured in Full space (4π) conditions.
2  Calculated maximum SPL based on rated power handling.

For polar plots, EASE modelling files, 2D and 3D drawings files, please check www.hhelectronics.com

SPECIFICATIONS

9

LEFT

FRONT

TOP

TOP BAFFLE

RIGHT

EN

Summary of Contents for Tensor TRM-1201

Page 1: ...ACTIVE STAGE MONITOR DESIGNED AND ENGINEERED IN THE UK WWW HHELECTRONICS COM TRM 1201...

Page 2: ..._____________________________ SPECIFICATION 5 _____________________________ INTRODUCTION GETTING STARTED 6 _____________________________ CONTROL PANEL 4 _____________________________ GENERAL INSTRUCTI...

Page 3: ...a la lluvia o humedad este aparato Antes de usar este aparato lea mas advertcias en la guia de operacion Afin de prevenir les risques de decharge electrique ou de feu n exposez pas cet appareil a la p...

Page 4: ...over 15 Never break off the ground pin Connect only to a power supply of the type marked on the unit adjacent to the power supply cord The U S Government s Occupational Safety and Health Administrati...

Page 5: ...nitoring solution The HH Tensor TRM 1201 Engineered in the UK to deliver power performance and reliability 100 120V setting VOLTAGE SELECT 100 120V 220 240V 220 240V setting VOLTAGE SELECT 100 120V 22...

Page 6: ...ing on or off 4 POWER INDICATOR Illuminates when the unit is connected to a suitable mains source and the Power Switch is set to on 7 GND LIFT A Ground lift has been provided to reduce the potential p...

Page 7: ...GND LIFT MODE STAGE MONITOR MODE For best results set the MODE switch to MONITOR on the TRM 1201 cabinets TRM 1201 STAGE MONITOR TRM 1201 STAGE MONITOR 11 FRONT OF HOUSE MODE In this example the MODE...

Page 8: ...solder pin view shown Balanced XLR 2 1 3 GND FEMALE 1 2 3 GND MALE 6 3mm mono jack 1 GROUND 2 HOT 3 COLD Unbalanced signal cables can be used for interconnects but are more sensitive to noise pickup e...

Page 9: ...20 240V 50 60Hz User Switchable AC Power Consumption 300W AC Power Inlet IEC C14 INLET Enclosure Cabinet Acoustically optimised Plywood cabinet with integrated carry handles Finish Painted Black Monit...

Page 10: ...els des produits destin s alerter l op rateur des zones ou des pr cautions suppl mentaires pouvant tre n cessaires 18 Cet quipement lectrique ne doit en aucun cas tre en contact avec un quelconque liq...

Page 11: ...et jack sym triques et asym triques Notez qu il s agit d une entr e sym trique un signal st r o ne peut pas tre connect cette prise 2 VOLUME Sert r gler le niveau de sortie global du TRM Pour rem die...

Page 12: ...tigkeit mit der derVerst rker zwischen geraden und schr gen R cken Positionen bewegt werden kann verwenden Sie nur denVerst rker auf einer ebenen stabilen Oberfl che NICHT denVerst rker auf einem Schr...

Page 13: ...signed and Engineered in the UK by HH Electronics LTD 2022 HH Electronics Ltd ACTIVE STAGE MONITOR LIVE SOUND BENUTZEROBERFL CHE PRESHAPE EQ MODES 12 DE 13 4 5 8 9 11 2 7 MODEL TRM 1201 10 1 6 3 MON F...

Page 14: ...no poner objetos que contengan l quidos como vasos sobre el aparato 1 Lea estas instrucciones 3 Haga caso de todos los consejos 11 Usar solamente componentes y accesorios proporcionados por el fabrica...

Page 15: ...ELTRASERO 12 ENCHUFE DE POSTE Al utilizar un tr pode est ndar de 35 mm observe las siguientes precauciones 9 INTERRUPTOR DE FUERZA Enciende y apaga el TRM Aseg rese de que el control de volumen est co...

Page 16: ...o Unido Se as cores dos fios do cabo de alimenta o da unidade n o correspondem com os terminais na ficha fa a o seguinte a O fio que colorido verde e amarelo tem de ser ligado ao terminal que est marc...

Page 17: ...ido para reduzir o problema potencial de realimenta o do sinal de terra ao conectar a outro equipamento Este controle deve ser usado em conjunto com a sa da Link caso o problema ocorra MONITOR Para us...

Page 18: ...Engineered in the UK by HH Electronics LTD 2022 HH Electronics Ltd ACTIVE STAGE MONITOR LIVE SOUND 4 9 I 15 16 2 17 a E b N c L 12 13 1 14 10 7 11 18 8 3 6 5 20 19 OSHA OSHA 2000m 2000m 21 CAUTION WAR...

Page 19: ...HH Electronics LTD 2022 HH Electronics Ltd ACTIVE STAGE MONITOR LIVE SOUND PRESHAPE EQ MODES 12 CN 19 6 XLR Combi 2 TRM 1 1 4 TRM 4 5 EQ FOH 3 LED led 7 MIX OUT 9 TRM 8 11 10 12 35mm 35mm 4 4 5 8 9 11...

Page 20: ...Designed and Engineered in the UK by HH Electronics LTD 2022 HH Electronics Ltd ACTIVE STAGE MONITOR LIVE SOUND KR CAUTION WARNING 20...

Page 21: ...REVISION 1 00 Model number Serial number Place of purchase Date of purchase hhelectronics www hhelectronics com hhelectronics hhelectronics...

Reviews: