background image

 

 

The bubbler is located 

laterally in the machine and

 serves two purposes: cleaning the Hydrogen gas and act as 

a safety barrier against a flame. If a flame reaches the bubbler and ignites the reduced hydrogen accumulated 
at the top of the bubbler but the water column will prevent the flame to reach the main tank where there is 
much more hydrogen accumulated. 

The  bubbler  comes  already  filled  with  a  light  acid  solution  from 
factory.  The  level  of  this  solution  should  be  kept  between  the  2 
marks in the metallic protection. If the level drops below the inferior 
mark then you should refill the bubbler. 

For refilling the bubbler, please follow these simple steps: 

1. The solution to use is a light acid, like vinegar (Ph 3); 

2. Open the threaded cap positioned on the top of the bubbler; 

3. With a small funnel, pure gently the solution and check at the 
same time the level rising inside the lateral hose of the bubbler; 

4. Stop pouring when the level reaches the maximum level mark; 

5. Close the threaded cap. If necessary add a little bit of Teflon tape 
to tight it better. 

 

 

Summary of Contents for HYDROGEN TECH ECC230 AC

Page 1: ...ECC230 AC User Manual...

Page 2: ...2 Refilling the main tank 5 3 3 Security Bubbler 5 4 Working with the machine 7 4 1 General use 7 4 3 Cleaning the air filter box 7 4 3 Working amperage 7 5 Diesel Cars and DPF Filter Cleaning 9 5 Mai...

Page 3: ...ear or in front of the end of the hose the protection bubbler inside the machine could blow up Be sure to wear goggles and rubber gloves and only use professional tools use common sense and general sa...

Page 4: ...nents of the machine Ammeter Water level lights Security Bubbler Water Tank Lid Ventilation Power Controls Emergency Switch Wheels Bubbler Cap Hydrogen Hose Power Cable AC Version Electric Plug Fronta...

Page 5: ...this light appears please stop adding electrolyte solution 6 Close the water tank lid making sure it is well tight 3 2 Refilling the main tank As you use the machine the water level inside the tank w...

Page 6: ...ory The level of this solution should be kept between the 2 marks in the metallic protection If the level drops below the inferior mark then you should refill the bubbler For refilling the bubbler ple...

Page 7: ...st 20 minutes of treatment increase the rotations of your engine to 1000 rpm and press second red power control button Check again amperage in the ammeter 9 Keep the machine working for one 1 hour to...

Page 8: ...the amperage is higher than 40A please add more water to dilute the solution and reduce the amperage b If the amperage is lower than 30A please add a little bit more electrolyte in order to raise the...

Page 9: ...right conditions the filter force the temperature of the exhaust gases to rise enough to burn the soot layers The regeneration process will not work properly when temperatures are low in winter for e...

Page 10: ...aintenance Depending on the working hours of the machine you should clean the machine and remove all deposits every six months Please follow these simple steps 1 Add 50 isopropyl alcohol to the water...

Page 11: ...wer 1200 kW HHO Gas Output Max 800 l h Max Pressure kg cm2 0 2 Max Water Consumption L h 0 20 Water refilling manual Water Tank Capacity 20 liters Autonomy 100 hours Dimensions L x l x h mm 400 x 500...

Page 12: ...EC Declaration of Conformity...

Page 13: ......