3.3 Predefined Seals 

 
The Hi-G-Tek enables to user to perform various operation on a DataSeal using HF RF. But 
in order to perform those operations the user need to supply the Seal ID of the DataSeal. 
One way is to physically take the DataSeal, read it’s it from the label put on it and type that 
ID manually. How ever there are times were there is a list of predefined seals the the user 
should work with. In this case, the user can put a file, “seals.txt”, with the list of those 
under the “\My Documents\Business\HiGTek\PredefinedSeals” folder. Each seal ID should 
be put in a new line as in the following example: 
 

IOBA08388686 
IABA01053175 
IFBA16777702 
IFBA16777667 

Figure 3:  seals.txt example 

 

Summary of Contents for IGMA51433/916

Page 1: ...UM4722 Rev 1 2A Master Hand Held Terminal IGMA51433 916 User Manual...

Page 2: ...ration 16 4 1 System Login 16 4 2 Main Screen 17 4 3 Select Seal Screen 18 4 4 Read reading DataSeal status data and events 19 4 5 Set arming the DataSeal 21 4 6 Read Data reading the DataSeal Data 22...

Page 3: ...sonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the...

Page 4: ...frequency channel Transmit Receive at 127 kHz AM 4 kHz data rate Hi G Tek HHT version 1 0 5 is a HandHeld Ternminal application running on a Pocket PC device equipped with Hi G Tek CF Reader The appl...

Page 5: ...RFID Module installation Carefully insert the RFID module into the CompactFlash slot of your PDA There is no need to install any drivers with this RFID card Please not that only one card may be used...

Page 6: ...t PC for the first time 1 Put the PPC on the cradle and plug in the USB connector to the PC 2 Windows XP should identify it as the new hardware 3 Install the ActiveSync 3 8 4 After installation ended...

Page 7: ...7 5 Make the above selections standard partnership and hit next You should get the following screen 6 Make the above selection w desktop and hit next You should get the following screen...

Page 8: ...8 7 Give a unique device name for each PPC device and hit next You should get the following screen 8 Make the above selection two computers and hit next You should get the following screen...

Page 9: ...9 9 Hit next You should get the following screen 10 Select file check box only and hit next You should get the following screen...

Page 10: ...10 11 Hit Finish The ActiveSync will be launched 12 After ActiveSync finish synchronize you should get the following screen...

Page 11: ...ows 14 Close the ActiveSync window 15 Double click on the above newly created shortcut 16 Open the Business directory 17 Create a new directory HiGTek and Open that directory 18 Create new directory S...

Page 12: ...Weight length 6 value desc Weight regex pattern d 1 6 valid err msg Invalid weight Must be upto 6 digits number For example 56233 fields settings Figure 1 settings xml example Where settings is the r...

Page 13: ...above If there is a need to change the data structure of the fields in the DataSeal the user or rather the system administrator should do the followings 1 Create a new settings xml file or update the...

Page 14: ...attribute name code type xs string xs attribute name name type xs string xs attribute name time type xs string xs attribute name stamp type xs string xs attribute name checksum type xs string xs attri...

Page 15: ...al read it s it from the label put on it and type that ID manually How ever there are times were there is a list of predefined seals the the user should work with In this case the user can put a file...

Page 16: ...ek HHT is launched the user is asked to provide the password for running the application This password is defined in the application settings settings xml file Figure 4 Login Screen Upon entering the...

Page 17: ...Seal Writing data to the DataSeal and setting its status to Set armed 3 Read Data reading data of an armed DataSeal 4 Write Data changing the data of an armed DataSeal 5 Verify searching for neighbori...

Page 18: ...arm There are three options for selecting DataSeal 1 Entering the Seal ID manually and hitting the respective select button The select button appears as disable as long as the user does not type a le...

Page 19: ...target DataSeal status data and events The Application reads the status and data first and then the events There are three tab pages in this screen General displays the DataSeal status as well as the...

Page 20: ...20 Figure 8 Read Screen Data Tab Page...

Page 21: ...and DataSeal events The DataSeal must be in a Closed state in order to successfully complete the Set process The user has to supply the data fields container ID Shipment Number etc to be written to th...

Page 22: ...ta reading the DataSeal Data Figure 10 Read Data Screen When hitting the Read Data button on the main screen the user is prompt select the target DataSeal and then after the application displays the R...

Page 23: ...he data fields in the DataSeal after it has been armed Set Typically the user will perform this operation if some mistake was made putting the data in Set screen The application reads first the fields...

Page 24: ...screen or on the The Verify screen enables there user to detect neighboring seals using RFID Verify broadcast message Seals receiving this message reply and the application adds them to the verify lis...

Page 25: ...on the main screen the user is prompt select the target DataSeal and the application starts the read process The Addressed Verify screen displays the target DataSeal status seal stamp and container I...

Reviews: