Total Station Manual
-
42 -
Steps
Key
Display
○
1
In the program of
Q-Survey, press [FNC] to
open the menu of Function,
next pressing [F2] to enter
the program of Offset.
[F2]
F1
[Function]
F2
F3
F4
F1 Level
F3 NP/P
F4 HT. Transfer
F2 Offset
(1)
(2)
(4)
(3)
1/3
○
2
Input the values of
Trav.OFS,
LengthOFS
and
HeightOFS, then select the
mode of offset and press [F4]
to save.
※
1
[F4]
Reset
[Dist. Offset]
Cylinder
Angle
OK
Trav.OFS:
LengthOFS:
HeightOFS:
Mode :
偏置模式 :
1.000 m
0.000 m
Rec/Reset
偏置模式 :
Input offset data!
2.000 m
※
1
:
Rec/Reset: Make sure the inputed values of Offset and reset all the values of Offset
to 0 after once measurement.
Permanent: The values of Offset are always working in the calculation of
measurement point.
2.2
Cylinder Offset
N
P0
Hz1
d
P1
R
R
Hz2
P0 Instrument station
P1 Center point of cylindrical object
Hz1 Horizontal angle to a point on the
left side of the object
Hz2 Horizontal angle to a point on the
right side of the object
d Distance to the object in the middle
between Hz1 and Hz2
R Radius of cylinder
α
Azimuth from Hz1 to Hz2
α
As for the not intervisible cylinders, you can measure the angles of station point
with cylinder in Hz Left and Hz Right and the shortest distance of station point to
cylinder firstly. Then calculate the coordinate of cylinder center and radius of
cylinder through the geometric relationships. The shortest distance between station
point and cylinder is in the bisector of angle of station point with cylinder in Hz Left
and Hz Right. Turning the instrument to make the collimation axis in the bisector of
Summary of Contents for HTS-420R