Total Station Manual
-
83 -
○
2 Press direction key and
move the cursor to input
prism height item. Input the
prism height and then press
[ENT] to confirm.
↓
+
Input
prism
height
+
[ENT]
*
ALL
DIST
REC
[Stakeout] 3/3
Search :
Pt. :
T.H :
Y/E :
X/N :
Z/H :
5
2.000 m
------
------
------
○
3 Aim at the prism. Press
[F2](DIST) to start measuring
and calculate the differences
between measured point and
stakeout point.
[F2]
*
ALL
DIST
REC
[Stakeout] 3/3
Search :
Pt. :
T.H :
Y/E :
X/N :
Z/H :
5
2.000 m
-0.306 m
0.404 m
-1.299 m
○
4 Move the prism along the
East direction to make the
value of
△
Y/E equal 0m.
△
Y/E is positive: The stakeout
point is in the right side of
measured point. Move the
prism to right.
△
Y/E is negative: The
stakeout point is in the left
side of measured point. Move
the prism to left.
*
ALL
DIST
REC
[Stakeout] 3/3
Search :
Pt. :
T.H :
Y/E :
X/N :
Z/H :
5
2.000 m
0.000 m
0.504 m
-1.299 m
○
5 Move the prism along the
North direction to make the
value of
△
X/N equal 0m.
△
X/N is positive: The
stakeout point is farther than
the measured point. Move the
prism far away the station.
△
X/N is negative: It needs to
move the prism close to the
station.
*
ALL
DIST
REC
[Stakeout] 3/3
Search :
Pt. :
T.H :
Y/E :
X/N :
Z/H :
5
2.000 m
0.000 m
0.000 m
-1.209 m