Total Station Manual
-
89 -
○
5 Press [
◄
] \ [
►
] to turn on
the error limits status and use
the key [
▲
] \ [
▼
] to move
the focus down to input the
every error limit. Then press
[F4] (OK) to set and back to
the [Resection] window.
Input
error
limits
+
[F4]
0.010 m
OK
[Set Error Limits]
e(Y/E) :
e(X/N) :
e(Z/H) :
0.010 m
0.010 m
Input error limits!
On
Status :
○
6 Press [F4] in [Resection]
window to start resection
measurement. It should be
input the station name and
the instrument high. Then
press [F4] (OK) go to next
step.
[F4]
Input
name
and IH.
+
[ENT]
[F4]
1.000 m
OK
[Resection-Station]
IH. :
DEFAULT
Station :
○
7 Set the first known point
and input prism high
。
※
1
The title bar will display
the number of known points
in the current setting.
1.500 m
Find
List
OK
[Resection-Target PT] 1
T.H. :
1
Pt. :
○
8
Turn the instrument
telescope aimed at first point
and press [F1] to finish
current measurement.
Angle measurement: press
[F2] (REC) to record an angle.
Distance measurement: [F1]
(ALL) or [F1] + [F2] (DIST +
REC).
[F1]
ALL
[Resection-Obserrve]
HA :
VA :
:
177°55′56″
89°15′12″
Pt. :
1
T.H. :
1.500 m
NEXT PT
Summary of Contents for HTS-420R
Page 1: ......
Page 11: ...Total Station Manual 10 1 Name and function of eachpart 1 Name ...
Page 12: ...Total Station Manual 11 ...
Page 192: ......