i
RTK5 Smart GNSS System User Manual
28
After doing the settings, the LCD will display the static data collection interface, and the static
measurement data will be saved in the host’s memory card. Users can download the static data file to
the computer as needed, and then use the static post-processing software (HGO data processing
software package) to process the data.
2.5.2 Static data collection steps
1. Set up the receiver on a control point, centering and leveling carefully.
2. Measure the height of the receiver three times, ensuring that the difference of each measurement is
less than 3mm. The final height of the receiver should be the average height. The height of the
receiver is measured from the center of the measuring point, to the top of the benchmark of the
receiver. The radius of the iRTK5 receiver benchmark is 0.130m, and the phase center is 0.0790m
high.
3. Record the point name, S/N, receiver height and beginning time.
4. Press the power button to power on and set up the static collecting mode.
5. Turn off the receiver after static data is collected and record the turn off time.
6. Download and post-process the static collection data.
Figure 2-5-1 Measure the antenna height