COMPARTMENT HEATER
The
Compartment Heater
is used to heat the equipment compartment during cold weather
operations when the unit is in use. It is connected to the chassis water system by valves mounted
on the unit. These valves must be opened to allow the hot engine water to flow to the compart
-
ment heater. They should be closed when the heater is no longer used.
The flow of water to the
Compartment Heater
is controlled by a
Push/Pull Cable
located on the
passenger side of the enclosure near the Hydro-X Hose Reel. Pushed all the way in, the flow of
hot water is closed off to the heater. Pulled, the hot water is allowed to flow to the heater.
The
Compartment Heater
fan is controlled by a
Thermostat
located near the Water Pump.
There is an “On/Off” switch for the
Compartment Heater
located in the cab.
PRINCIPLES OF OPERATION 15
AQUATECH OPERATIONS, SERVICE AND PARTS MANUAL
A Product of Hi-Vac Corporation
PRINCIPLES OF OPERATION