The Safety system
4.11.1
4.11.1 Indicator LEDs on user panel
SPACE 5000
Power On
①
Green light on: The system is on
Green light flashing: A stop button is depressed.
Service
②
Green light on: Time to service the crane.
Red light on: A non-critical error detected in the
system.
Red light flashing: Critical error is stopping the
crane. Diagnostic required.
Red double flash: CAN error, crane stops.
OLP Release
③
Red light on: OLP
Red light blinking: OLP release button has been
pressed. 5 sec to release OLP.
VSL: Variable
④
Green light on:Full VSL stability
Stability Limit
Light off: Vehicle has limited stability but, crane
capacity is not fully used.
Red light on: VSL OLP. Vehicle has reached a
stability limit. (Also all the 1st boom diodes will light
red).
⑤
Green light on: Dump valve 1 activated.
Automatic duty
⑥
Green light on:
control
Increased capacity (ADC mode)
Hoist LED
⑦
Green light on: Hoist mode.
Red light flashing: 90% of OLP pressure
Red light on: 100% of OLP pressure
48