➀
70%
90%
100%
50%
During operation
6.1
OLP Boom system
Warning at 50%, 70%, 90% and 100% visible
on the controller
• The pressure in the cylinders is displayed as a
percentage of the maximum permitted pres-
sure.
• The percentage pressure loading in the cylin-
der is displayed in the window of the respec-
tive lever as a number: 50%, 70%, 90% and
100%.
• When the pressure is 50% or more, the
percentage alternates with the lever symbol
once a second.
• When a pressure sensor reaches 100 %, all
motions that would increase torque are
blocked.
• If the operator attempts to activate a blocked
function, the function symbol is replaced by a
cross while the lever is deflected. When the
lever is returned to the neutral position, the
cross disappears and the information returns.
Operate permitted (load reducing) functions
only.
NOTE
Do not operate heavy loads with the extensions
fully retracted. In an OLP situation it is an
advantage to be able to retract the extensions.
Warning at 50%, 70%, 90% and 100% visible
on the user panel
• Indicator LEDs
①
are flashing on the user
panel when load is close to rated capacity and
light up at rated capacity.
74
Operator's Manual GB