➀
Maintenance and Service
8.5.6
WARNING
• Inhalation of oil mist: Contact a doctor.
• Skin contact: Remove polluted clothing,
wash with soap and water. In the event of
high pressure injection of the product, see
a doctor without delay.
• Eye contact: Rinse eyes with plenty of
water, see a doctor if irritation persists.
3. Drain the oil tank through the drain plug
①
. Make sure the system contains as little
as possible.
The capacity of the tank is 40-235 litres
(10.6-62 gallon). Use a container with suffi-
cient capacity.
NOTE
Ensure the waste oil is disposed of safely and
inaccordance with local environmental regula-
tions.
4. Change at the same time:
- all filters
5. Refit the drain plug.
Filling the oil tank with hydraulic oil
The oil used for filling must be clean. Do not mix
different oils.
Hydraulic oil that is approved for HIAB products
must comply with one of the following standards
or equivalents:
-DIN 51524 part 3
-SS 15 54 34
-ISO 11158 HV
Suppliers of hydraulic oil must verify that the
quality and performance of the oil complies with
the above standards.
When changing from mineral oil to a non-
polluting synthetic oil, or when changing to
biodegradadle oil, contact a HIAB service work-
shop.
Operator's Manual GB
95