➀
During operation
6.1
To release OLP (CombiDrive2)
In certain OLP situations, the first and second
booms can be locked. It is then possible to
release the OLP for approximately 5 seconds, by
pressing the button
①
on the right hand side
below the display handle. There is a waiting time
before the release operation can be activated
again. The time increase in three steps: 30, 60
and maximum 90 seconds (the time starts to
count down as you move the lever).
During this period it is possible to operate an
appropriate crane function so as to correct the
overload situation. Only one unallowed function
at a time can be operated. Extension out cannot
be operated.
The unlocked padlock will appear in the centre
display.
On the user panel the cylinder pressure LEDs and
the LED for padlock symbol will flash red.
Manual control
If one prohibited movement is used, all move-
ments will stop. The crane will be fully opera-
tional as long as only allowed movements are
used.
DANGER
Only use the OLP override to get the crane out
of a locked position. Never use the OLP
override to overload the crane deliberately!
Operator's Manual GB
75