The Safety system
4.8.1
Service
②
Green light on: Time to service the crane.
Red light on: A non-critical error detected in the
system.
Red light flashing: Critical error is stopping the
crane. Diagnostic required.
Red double flash: CAN error, crane stops.
OLP Release
③
Red light on: OLP.
Red light blinking: OLP release button has been
pressed. 5 sec to release OLP.
Slewing sector [op-
④
Light off: Inside slewing sector, reduced capacity.
tion]
Red light on: OLP. Vehicle has reached a stability
limit. (Also all the 1st boom diodes will light red).
VSL: Variable
④
Green light on: Full VSL stability.
Stability Limitation
Light off : Vehicle has limited stability but, crane
[option]
capacity is not fully used.
Red light on: VSL OLP. Vehicle has reached a
stability limit. (Also all the 1st boom diodes will light
red).
Automatic duty
⑥
Green light on:
control [option]
Increased capacity (ADC mode)
Hoist LED
⑦
Not active.
Cylinder pressure
⑧
Green light A on: 50% of OLP pressure.
LED's
Green light A-B on: 70% of OLP pressure.
Red light A-C flashes: 90% of OLP pressure.
Red light A-D on: 100% of OLP pressure.
Red light blinking from A-D: OLP release.
Remote control
⑨
Green light on: Remote control. Good radio connec-
tion.
Green light blinking: Stop button pressed/no radio.
connection.
Red light blinking: Radio interference.
Manual extensions
⑩
Not active.
Manual control
⑪
Green light on: Manual control.
Stabiliser system
⑪
Green light on: The stabiliser system is ready to use.
⑫
Operator's Manual GB