1
The Safety system
4.9
Micro / SRVC / MEWP / Manual extension /
LSS / HDC / JDC / ADC
When one of the above functions is activated or
engaged, the symbol is enlarged for three sec-
onds. It then returns to its normal size. This is to
show the operator that a change has happened.
Error indication
This symbol, a spanner, appears if the Safety
System has discovered a fault in the system.
Non critical error
Symbol appears enlarged in the center of the
display. After three seconds it returns to normal
size and moves to the upper part of the display.
Critical error
Symbol remains enlarged in the center of the
display. The crane stops.
Error code display
The control system, has the possibility to send
error codes to the controller. By pressing button
①
, on the left-hand side below the display
handle. The centre display changes state to show
the error codes.
If there are more than six error codes at the same
time, the six most recent ones sent from the
control system, are shown.
Operator's Manual GB
49