The Safety system
4.11
4.11 Battery charger CD2
The battery charger is to be fitted in a protected
environment, preferably in the cab. Two batteries
are delivered with each unit, one of which can
always be placed in the charger.
Display A
①
lights when the charger is activated.
①
and
②
lights during charging.
①
and
③
lights when the battery is fully
charged.
Display B
Shows the battery voltage (8.4).
When the display blinks 0.0 there is error in the
battery: Change battery.
Charging time
The normal charging time for an flat battery, is
approximately 3 hours. The battery charger is
designed not to damage the battery, even during
long continuous charging.
Operating ambient temp:
Battery = 0° to + 45°C.
A charged battery
The voltage level of a fully charged battery is
approximately 8,4V and it provides about 5-8
hours working time. Note that the battery voltage
remains between 7,6V and 7,5V for a long time.
Therefore, the battery voltage cannot be used to
estimate the working time.
! NOTE
A charged battery is a concentrated energy
source. Never store a charged battery in a toolbox
or similar, where there is a risk of a short due to
metal components.
Used batteries should be taken care of according
to the local regulations.
Operator's Manual GB
57