100%
During operation
6
6.1
OLP (Overload protection)
OLP HiPro crane
The OLP function is a safety function in SPACE
that prevents overloading of the crane.
With 90% of maximum permitted load, a pre-
warning is given.
The warning lamp [option] on the stabiliser leg
double blink and the cylinder pressure LED's
flash red.
The yellow lamp on the lamp pole [option]
flashes and the cylinder pressure LED's flash red.
When 100% of the maximum permitted pressure
is reached, the OLP cuts in. The display shows
whether a particular motion is prohibited or if the
crane is subject to OLP. The warning lamp
[option] on the stabiliser leg will flash twice , the
red and the amber lamps on the lamp pole
[option] will light all the time and the cylinder
pressure LED's will light continuously.
Operator's Manual GB
69