96
Maintenance and Service
Operator's Manual GB
9.6.3
Press the button again to return to Use time
mode.
Example: 3 active errors, 003, 014 and 028
Clear errors
In Error display mode, errors can be cleared (as
in SPACE terminal) by pressing the button for 2
seconds until the clear errors symbol
is
shown in the display.
9.6.3 Faults in the hoist
Faults in the hoist must be rectified immediately.
DANGER
• Only correct yourself the faults that ac-
cording to the table you may rectify.
• Follow the instructions exactly!
• All other faults may be dealt with only by
personnel in a HIAB service workshop!
Symptom
Probable cause
Action
Hoist will not hoist/pull rat-
ed load.
Inadequate hydraulic system
supply pressure.
Verify hydraulic system
supply pressure and correct
as required.
Damaged hoist motor.
Go to a HIAB service work-
shop to have the motor re-
placed.
Hoist center line is distorted
due to uneven mounting sur-
face.
Contact a HIAB service
workshop.
Binding load carrying
sheaves.
Inspect and repair or lubri-
cate sheaves as required.