Emergency operation
CAUTION!
Internal safety functions of the device do not work
in manual control mode. Therefore, be especially
careful when carrying out the movements.
If a failure happens in the
electric system of the device,
the device may be restored to
its normal state, by operating
the control valve manually:
1. Press down the button
located at the end of
valve for needed direction
(101 or 114) and hold it
down.
2. Press down the button
located at the end of free
circulation valve (108).
3. Release the buttons
when you would like to
stop the movement.
Note!
The valve stem return spring (101 or 114) is
rather rigid and requires effort to push the button
to the bottom.
You can use the emergency movement lever
MU111568801 (additional equipment, located
behind the valve stand) as an auxiliary tool.