ERROR CODE
COMMENTS / PROBLEM
LOCATION
PROGRAM DESCRIPTION
POSSIBLE ACTION
CONSEQUENCE
FAULTS
-7F-
CAN BUS NOT ABLE TO COMMUNICATE WITH CONTROL BOX
CAN LINKING
HARNESS
CAN BUS SIGNAL IS
MISSING
CHECK YELLOW AND GREEN WIRE BETWEEN CONTROL
UNIT AND 2024 MODULE
TOTAL STOP OF
SYSTEM
F000
SUPPLY VOLTAGE IS BELOW 16 VOLTS
TRUCK
LOW POWER
CHARGE TRUCK BATTERY
TOTAL STOP OF
SYSTEM
F001
INTERNAL ERROR ON 2024
2024
INTERNAL ERROR 1
REPLACE 2024 IF ERROR REPEATS
F002
INTERNAL ERROR ON CONTROL BOX
CONTROL BOX
INTERNAL ERROR 2
REPLACE CONTROL BOX IF ERROR REPEATS
F003
VALUES FROM PRESSURE SENSOR NOT LEGAL
2024
PRESSURE SENSOR
CHECK CONNECTION / REPLACE SENSOR
NO ACTION
F004
INTERNAL PARAMETER ERROR
2024
PARAMETER
CHECK PARAMETERS / REPLACE MAIN BOX
NO ACTION
F005
CAN BUS NOT ABLE TO COMMUNICATE WITH 2024
ANY POSITION
TIME OUT 1
CHECK BOX/CAN BUS WIRE & REPLACE IF NECESSARY
NO ACTION
F006
CAN BUS NOT ABLE TO COMMUNICATE WITH CONTROL BOX
ANY POSITION
TIME OUT 2
CHECK BOX/CAN BUS WIRE & REPLACE IF NECESSARY
NO ACTION
F007
PROGRAM HAS STOPPED RUNNING
2024
NOT RUNNING
POWER OFF/POWER ON TO RESET
NO ACTION
F008
CAN BUS NOT ABLE TO COMMUNICATE WITH ANY BOX
ANY POSITION
CAN BUFFER OVER RUN
CHECK CAN BUS WIRE & REPLACE IF NECESSARY
NO ACTION
F009
not used