139
4/2018
113175421
XR14S/16S/18S/21S/26S/30S
Hooklift Multilift XR S
Service Manual
ERROR CODE
COMMENTS / PROBLEM
LOCATION
PROGRAM DESCRIPTION
POSSIBLE ACTION
CONSEQUENCE
C010
TIPPING LOCK OPEN IS 1 AND TIPPING LOCK CLOSED IS 1
HOOKLIFT
INPUTS CONFLICT 4
CHECK TIPPING LOCK OPEN AND TIPPING LOCK CLOSED
SENSORS - REPLACE IF NECESSARY
C011
JOYSTICK VALUE TOO SMALL
CONTROL BOX
JOYSTICK CONFLICT
CALIBRATE JOYSTICK - REPLACE IF NECESSARY
C012
JOYSTICK VALUE TOO BIG
CONTROL BOX
JOYSTICK CONFLICT
CALIBRATE JOYSTICK - REPLACE IF NECESSARY
C013
JOYSTICK HIGH VALUE WITHOUT DIRECTIONAL SWITCH,
CENTER TAPP IN MIDDLE
CONTROL BOX
JOYSTICK CONFLICT
CALIBRATE JOYSTICK, CHECK WIRES - REPLACE IF
NECESSARY
C014
JOYSTICK LOW VALUE WITHOUT DIRECTIONAL SWITCH,
CENTER TAPP IN MIDDLE
CONTROL BOX
JOYSTICK CONFLICT
CALIBRATE JOYSTICK, CHECK WIRES - REPLACE IF
NECESSARY
C015
JOYSTICK HIGH VALUE WITHOUT DIRECTIONAL SWITCH,
CENTER TAPP NOT IN MIDDLE
CONTROL BOX
JOYSTICK CONFLICT
CALIBRATE JOYSTICK, CHECK WIRES - REPLACE IF
NECESSARY
C016
JOYSTICK LOW VALUE WITHOUT DIRECTIONAL SWITCH,
CENTER TAPP NOT IN MIDDLE
CONTROL BOX
JOYSTICK CONFLICT
CALIBRATE JOYSTICK, CHECK WIRES - REPLACE IF
NECESSARY
C017
JOYSTICK VALUE 255
CONTROL BOX
JOYSTICK CONFLICT
CHECK JOYSTICK WIRES (GND) - REPLACE IF NECESSARY
C018
JOYSTICK VALUE 0
CONTROL BOX
JOYSTICK CONFLICT
CHECK JOYSTICK WIRES (SUPPLY VOLTAGE / SIGNAL)
- REPLACE IF NECESSARY
C019
CENTER TAPP NOT IN MIDDLE
CONTROL BOX
JOYSTICK CONFLICT
CHECK JOYSTICK WIRES (CENTER TAPP)
- REPLACE IF NECESSARY
C020
INPUT PRESENT AT START UP
CONTROL BOX
SWITCH CONFLICT
DO NOT PRESS SWITCHES WHILE CONTROL BOX IS
STARTING / CHECK AND REPLACE FAULTY SWITCHES
Summary of Contents for Hooklift Multilift XR S Series