radio connection is established, the system will stop and the reset by pressing emergency stop is
required.
1. Make sure that all the levers are in neutral positions and that spools can move freely in their
valves.
2. Make sure that levers and the spools cannot be blocked.
3. Make sure that levers on the controller operate correctly.
E013: Service!
This error shows when one of the service counters (calendar days, hours, use time or number of
lifts) has reached the limit (the error led lamp on the User Interface is on with a steady green
colour).
• Go to a Hiab authorised service workshop.
E016: Remote battery empty
1. Recharge or change the battery in the controller.
E017: Controller
1. Push the emergency stop button and then release it. If you can still see the error, go to a Hiab
authorised service workshop.
E056: JIB plug conflict
1. There is probably a short circuit inside the JIB plug. Clean the JIB cable connector and the JIB
plug.
2. Put electric grease on both the connector and the JIB plug.
3. Set the system to OFF and then back to ON. If you can still see the error, go to a Hiab
authorised service workshop.
E186: SAF
This error appears only when you move a lever for SAF.
SAF - Slew is in cabin sector
The SAF function cannot start because the crane is positioned in a specified sector where SAF is
not available (for example: OLP sector, cabin sector, OPS sector, etc.). Change the crane position
and activate SAF again.
SAF – Crane not in position
If the boom system is almost folded but the slew is not in the permitted area, the unfolding function
cannot start. The solution is to fold the crane manually, and then the unfolding can be done with the
SAF function.
E194: SAF
Refer to E186.
Maintenance and Service
HIAB L-HiPro 145/165/195/235
115