5.2.1. Stabiliser system and ground conditions
Always:
• Make sure that the ground can support the load that
the stabiliser leg imposes on the ground.
(*)
• Make sure that the ground is not undermined.
• Use the extra support plates that are large and firm
enough for your crane model.
The maximum permitted ground inclination under
the stabiliser leg plate is 5º.
(*) The maximum load that the stabiliser leg can impose on the ground:
X-Cranes
L-Cranes
Z-Cranes
S-Cranes
P (kN)
128/138/142/148/158/162/
178/188/192
135/145/155/165
171/191
145
218/228/232
195/225/235
230
175
248/258/262/288/298/302
220
NOTE
Sign that shows the maximum force that the stabiliser
legs can apply to the ground.
Starting crane operation
HIAB L-HiPro 145/165/195/235
65