JDC
55
The HiPro system
Operator's Manual GB
4.6.1
Service
Green light on: Service needed.
Red light on: Error in the system.
Red light blinking: Critical error.
Dump valve
Blue light on: Dump activated.
ADC
Blue light on: Crane has enhanced capacity (ADC
mode).
Hoist
Green light on: Hoist mode.
Red light flashing: 90% of OLP pressure.
Red light on: 100% of OLP pressure.
JDC
Blue light on: Outermost extension fully retracted
and the JIB has increased capacity (JDC mode).
VSL-OLP
Not active in this configuration.
Stabiliser legs
Not active in this configuration.
Stability sector
Green light on: regardless of the situation.
Cylinder pressure
1 of 4 green light on: 50% pressure.
2 of 4 green light on: 70% pressure.
3 of 4 red blinking light: 90% pressure.
4 of 4 red light on: 100% pressure.
4 of 4 red running light: OLP release activated.
LED test for the user panel, see Daily inspec-
tion.