➀
➁
➂
A
B
➀
➀
73
The HiPro system
Operator's Manual GB
4.11.4
4.11.4 Battery and battery charger
Battery
The voltage level of a fully charged battery is
approximately 8,4V and it provides about 5-8
hours working time. Note that the battery voltage
remains between 7,6V and 7,5V for a long time.
Therefore, the battery voltage cannot be used to
estimate remaining hours of use.
Install a fully-charged battery in the controller as
shown on the right. It is important to fit the
battery the right way round. If the battery is
upside-down the controller will not start.
Battery charger
The battery charger is to be fitted in a protected
environment, preferably in the cab. Two batteries
are delivered with each unit, one of which can
always be placed in the charger.
Normal charging time for a flat battery, is
approximately 3 hours. Operating ambient temp:
Battery = 0° to + 45°C.
Display A
①
lights when the charger is activated.
①
and
②
lights during charging.
①
and
③
lights when the battery is fully
charged.
Display B
Shows the battery voltage (8.4).
When the display blinks 0.0 there is error in the
battery: Change battery.
! NOTE
A charged battery is a concentrated energy
source. Never store a charged battery in a toolbox
or similar, where there is a risk of a short due to
metal components. Used batteries should be taken
care of according to the local regulations.