LSS
OFF
LSS
ON
LSS
ON
LSS
OFF
4 5
7 8
5
96
During operation
Operator's Manual GB
6.2
Activate and deactivate LSS-V (By default)
with the controller CombiDrive
1. Press the ON-OFF button
⑤
on the remote
control.
• CombiDrive with 6 levers: Menu 2 ON-OFF
• CombiDrive with 8 levers: Menu 1 ON-OFF
2. Move the levers according to the text in the
display.
• CombiDrive with 6 levers: lever 4 (activate)
and lever 5 (deactivate).
• CombiDrive with 8 levers: lever 7 (activate)
and lever 8 (deactivate).
6.2
OLP (Overload protection)
OLP is a safety function that prevents overload-
ing of the crane. With 90% of maximum permit-
ted pressure the amber lamp on the lamp pole, if
present, flashes.
OLP boom system
When 100% of the maximum permitted pressure
is reached, OLP cuts in and stops all functions
that increase the pressure. On the lamp pole, if
present, the red lamp and amber lamp will light
continuously.
The pressure level in the first and second boom is
indicated by the LEDs on the user interface:
• 50% of maximum pressure – 1 of 4 LEDs
light green
• 70% of maximum pressure – 2 of 4 LEDs
light green
• 90% of maximum pressure – 3 of 4 LEDs
flash red
• 100% of maximum pressure – 4 of 4 LEDs
flash red