87
During operation
Operator's Manual GB
6.4
6.4
To release OLP
If all functions have been blocked due to OLP it
is possible to temporarily release OLP and oper-
ate an appropriate crane function to correct the
overload situation. OLP release is active in 5
second intervals. After each 5 second interval of
OLP release there is a wait before the release
operation can be activated again. The wait will
increase in three steps: 30, 60 and maximum 90
seconds. During each 5 second interval only one
function at a time can be operated. Extension out
cannot be operated at all. The 5 second interval
starts to count down as you move the lever.
DANGER
Only use the OLP release to get the crane out
of a locked position. Never use the OLP
release to overload the crane deliberately!
OLP release on user panel
Push and hold button
on the user panel whilst
operating load reducing functions. The cylinder
pressure LEDs on the user panel perform a
running light. The LED for padlock symbol will
blink red.
OLP release on controller XSDrive
Push and hold the button
on the controller
whilst operating load reducing functions. On the
user panel the cylinder pressure LEDs perform a
running light. The LED for padlock symbol will
blink red.