XXXX Kg
XXXX Lbs
Max
1 2
89
During operation
Operator's Manual GB
6.5
To lift heavier loads than specified on the sign
③
, the hook position must be moved to the
nearest hydraulic extension, in accordance with
the load plate on the crane.
To retract the manual extensions
1.
Locate the boom system as close as possible
to the horizontal position, but low enough to
reach the extension by hand.
2.
Stop the crane, by pushing the stop button.
3.
Remove the locking device
①
and the
locking pin
②
.
4.
Retract the manual extension fully by hand.
5.
Secure the manual extension, by locking the
pin
②
and locking device
①
.
DANGER
• Make sure that the locking device is
properly locked.
Activate and de-activate OLP for manual ex-
tensions on the user panel
WARNING
You must switch the OLP on and off manually
for additional manual extensions!
Activate:
Push button
on the user panel.
The manual extensions are now included in the
OLP protection. The lifting capacity will be
reduced automatically. The lamp for
lights up
on the user panel.
De-activate:
Push the button again. The lamp for
goes out.