Replacing the Chamber Block
STEP
8
STEP
8
Check that the broken screw is removed from unit.
●If the broken pin is left inside the unit, it can get caught
in between electromagnets and actuating rod, which
can cause breakdown.
STEP
9
STEP
9
Insert a new safety pin through the hole on the
terminal side.
(Please Insert safety pin through the spring
electrode, L-shaped lever in such order.)
STEP
10
STEP
10
Install the locking collar from the other side of the
terminal and insert it until it clicks.
STEP
11
STEP
11
This completes the replacement of the safety pin
procedure.
Make sure the gaps between L-shaped lever and
tab of the actuating rod is even.
●Be careful not to touch the terminal when the power is
on, testing the operating conditions as this will result in
an electric shock.
●Unplug the pump immediately after the check.
HP-
60/80
REPLACING THE CHAMBER BLOCK
REPLACEMENT OF SAFETY PIN