background image

Edge is the next evolution in access control hardware solutions. A true IP solution that meets the demands of open architecture, IP-centric 

environments, Edge provides fully distributed intelligence and decision making right to the door, leveraging the IT infrastructure to the 

maximum extent possible. Wire the Edge device to Hi-O interface modules to provide connectivity to electronic door components and 

access control readers.

Hi-O involves devices with built-in intelligence and a CANbus that links all the devices together. Hi-O CANbus data traffic can be password 

protected and encrypted, or both. Each Hi-O device (such as the push plate, electric strike, card reader, door operator) is connected to the 

CANbus by a single, four-wire cable. Two of the wires supply power and the other two are used for data communication.

Specifications

CONNECTION

PARAMETER

CONDITIONS

VALUE

OPERATING 

TEMPERTURE

CABLE LENGTH

PoE Power 

(input)

Voltage - Nominal

-

48 VDC

32° - 122°F

(0° - 50° C)

Hi-O CAN Bus

 

= 30 ft (9 m) 

-  22 AWG ● 0.65mm ● 0.33mm

2

 

= 75 ft (23 m) 

-  18 AWG ● 1.02mm ● 0.82mm

2

RJ45

 

= 328 ft (100 m) 

-  Category 5 K

Current - Normal Standby 

Condition (NSC)

CAN PWR - not loaded

75 mA

Current - Maximum

CAN PWR - max load

275 mA

 +DC (input)

Voltage

-

12 VDC - 24 VDC

Current - Normal Standby 

Condition (NSC)

12 VDC

CAN PWR disconnected

190 mA

Current - Normal Standby 

Condition (NSC)

24 VDC

CAN PWR disconnected

110 mA

Current - Maximum

12 VDC

2.2 A

Current - Maximum

24 VDC

2.1 A

CAN PWR 

(output)

Voltage - Nominal

PoE

24 VDC

Current - Maximum

PoE

300 mA

Voltage - Nominal

+ DC

+ DC

Current - Maximum

+ DC

2 Amp - AUX limited

Edge

EdgeReader® and EdgePlus®

Models: 

EH400, EHR40, EHRP40, EH400-K

 ER40C, ERP40C

I

nstallatIon

 G

uIde

82000-920, Rev A.1

December 10, 2009

© 2009 HID Global Corporation.  All rights reserved.

15370 Barranca Parkway

Irvine, CA 92618-2215

USA

DRAFT