background image

installation
instalación
installation
instalação
installation
installazione

安装

取り付け

설치

Установка

SmartID

by

®

S10 / SK10

SP10 / SPK10

Add Picture

Weather

Protector

paRts

1 - SmartID Reader 

• 

1 - Installation Guide

• 

2 - 3.5 mm x .6 pitch x16 mm Phillips machine screws

• 

2 - .138-32 x .625 Phillips machine screws

• 

2 - .138-20 x 1.5 FL-82 Phillips AB

• 

1 Screw Cap

• 

Recommended

Cable, 5-9 conductor (Wiegand or RS232), 22 AWG shielded (pigtail) 

• 

Linear DC Power supply

• 

Metal or plastic junction box 

• 

Security Tool (for anti-tamper screw) HID 04-0001-03

• 

1

a

sseMBly

 

and

 

disasseMBly

M

ontaJe

 

y

 

desMontaJe

M

ontage

 

et

 

déMontage

M

ontageM

 

e

 

desMontageM

z

usaMMenBau

 

und

 

zeRle

-

gung

M

ontaggio

 

e

 

sMontaggio

组装和拆卸

組み立てと解体

조립 및 분해

сБоРка и РаЗБоРка

PRODUCT

BASE PART 

NUMBER

INPUT 

VOLTAGE

CURRENT

OPERATING 

TEMPERATURE

CABLE 

DISTANCE

AVERAGE

PEAK

S10

SK10

8030
8031

5-24 VDC

600 mW

?? mA

1000 mW

?? mA

-22° - 140°F

(-30° - 60° C)

Wiegand  =   500 ft  (153 m) - 18 AWG
 

 

 300 ft (91 m)  - 20 AWG

 

 

 200 ft (61 m)  - 22 AWG

Clock -and-Data
 

 

82 ft (25 m) 

- 22 AWG

RS232     =  50 ft (15.24 m)
RS485     =  4000 ft (1,219.2 m)

HID / AWID Prox

SP10

SPK10

8100
8101

5-24 VDC

1400 mW

?? mA

2100 mW

?? mA

-22° - 140°F

(-30° - 60° C)

Indala Prox

SP10

SPK10

8140
8141

5-24 VDC

1300 mW

?? mA

1600 mW

?? mA

-22° - 140°F

(-30° - 60° C)

w

iRing

C

aBleado

C

âBlage

F

iação

V

eRdRahtung

C

aBlaggio

布线

配線

배선

Э

лектРические

 

соединения

2

ATTENTION

Observe precautions for handling

ELECTROSTATIC SENSITIVE DEVICES

**  LED input only valid in read-only applications.

CAUTION

: 5 VDC is minimum voltage at reader connector pins.

Tamper contact (optional): Rating 1A 30 VDC.

Term Clock-in-Data (ABA) Wiegand

RS232

RS422

RS485

P1

Green LED (GRN)

Green LED (GRN)

Green LED (GRN)** Green LED (GRN)** Green LED (GRN)**

P2

Red LED

Red LED

Red LED**

Red LED**

Red LED**

P3

Data

D1

Do not connect (NC) TXA

TRX

P4

Clock

D0

TXD

TXB

TRX

P5

Buzzer Input

Buzzer Input

Do not connect (NC) RXA

Do not connect (NC)

P6

Do not connect (NC)

Do not connect (NC) RXD

RXB

Do not connect (NC)

P7

Ground (GRD)

Ground (GRD)

Ground (GRD)

Ground (GRD)

Ground (GRD)

P8

Power (PWR)

Power (PWR)

Power (PWR)

Power (PWR)

Power (PWR)

Turn on power

Encienda la unidad

Mettez sous tension

Ligue a energia

Einschalten

Accendere

打开电源

電源を入れます

전원을 켜십시오

включить питание

Test card

Pruebe la tarjeta

Testez la carte

Teste o cartão

Karte testen

Provare la tessera

测试卡

カードをテストします

카드를 테스트하십시오

тестовая карта

p

oweR

 & 

testing

e

nCendido

 

y

 

pRueBa

a

liMentation

 

et

 

test

F

oRça

 

e

 t

este

s

tRoMVeRsoRgung

 

und

 

testen

a

CCensione

 

e

 

pRoVa

电源和测试

電源投入とテスト

전원 및 테스트

в

ключение

 

питания

 

и

 

пРовеРка

3