background image

2) Pump Replacement Parts

Item

Product Description

Item

Product Description

1

Tie-in Nut

13

O-Ring

2

Tie-in

14

Difusser

3

O-Ring

15

Activities Rings

4

Drainge Plug

16

Impeller

5

O-Ring

17

Mechanical seal

6

Pump casing

18

Pump cover

7

Filter

19

Pad

8

O-Ring

20

Hexagon bolt

9

Transparent cover

21

O-Ring

10

Gland cover of Transparent cover

22

Retaining block

11

Open Cover Wrench

23

Motor

12

O-Ring

Release allairfrom filter and piping system.
In a flooded suction system (water source higher than pump), pump will prime itself when suction and 
discharge valves are opened.
If  pump is not in a  flooded suction system,  unscrew and remove  trap cover; fill trap and pump with 
water.
Clean and inspect Ring; re-install on trap cover.
Replace trap cover on trap; tum clockwise to tighten cover.
NOTICE:  Tighten  trap  cover  by  hand  only.  Pump  should  prime  now.  Priming  time  will  depend  on 
vertical length of suction lift and horizontal length of suction piping.

Figure 3

Summary of Contents for Filtration Combo Series

Page 1: ...Filtration Combo Series VC Series USER MANUAL ...

Page 2: ...stic clamps from tank neck b Cap internal pipe with plastic cap to prevent sand from entering it c We recommend filling tank approximately 1 2 way with water to provide a cushion effect when the filter sand is poured in This helps protect the under drain laterals from excessive shock d Carefully pour in correct amount and grade of filter sand Be sure center pipe remains centered in opening Sand su...

Page 3: ... the filter for water leaks and tighten the connections bolts nuts as required 6 Acknowledge the initial pressure gauge reading when the filter is clean It will vary from each pool depending on the pump and general piping system As the filter removes dirt and impurities from the pool water the accumulation in the filter will cause the pressure to rise and flow to diminish When the pressure gauge r...

Page 4: ...rench 23 Motor 12 O Ring Release allairfrom filter and piping system In a flooded suction system water source higher than pump pump will prime itself when suction and discharge valves are opened If pump is not in a flooded suction system unscrew and remove trap cover fill trap and pump with water Clean and inspect Ring re install on trap cover Replace trap cover on trap tum clockwise to tighten co...

Page 5: ...Drain Plug with O ring 1 26 Pressure Gauge with O ring 40psi 1 5 Valve Positions Function Valve Position Function FILTER Normal Filtration and Vacuum BACK WASH Clean Filter by reversing the flow RINSE Use after backwash to flush dirt from valve WASTE By passes filter use to vacuum the waster for lowering water level RECIRCULATE By passes filter for circulating water to pool CLOSED Shut off all flo...