3) Multiport Valve Replacement Parts

Item

Product Description

Qty

1

Handle (Big)

1

2

Pin for Handle

1

3

Washer for Handle

1

4

M6*30 Screw with Nut for Standard Lid

6

5

1.5" Top Mount Valve Standard Lid (Black)

1

6

O-ring for 1.5" Valve Lid

1

7

Washer for Spring

1

8

Spring for 1.5" Top Mount Valve

1

9

O-ring for 1.5" Valve Rotor

2

10

1.5" Valve Rotor

1

11

Spider Gasket

1

12

1.5" Top Mount Valve Bottom Body Clamp (black)

1

13

1.5" Diffuser

1

14

O-ring for Diffuser

1

15

1.5" Top Mount Valve Over Drain Diffuser

1

16

O-ring

1

17

O-ring for 1.5" Connector

3

18

1.5" Connector (Black)

3

19

O-ring for 1.5" Union

3

20

1.5" Union (A/E)

2

21

1.5" Union Nut (black)

3

22

1.5" Union with sight glass (short)

1

23

1.5" Union with sight glass holder

1

24

Connector for pressure gauge/stopper

1

25

Drain Plug with O-ring

1

26

Pressure Gauge with O-ring (40psi)

1

5. Valve Positions Function

Valve Position

Function 

FILTER

  Normal Filtration and Vacuum

BACK WASH

  Clean Filter by reversing the flow

RINSE

  Use after backwash to flush dirt from valve

WASTE

  By-passes filter, use to vacuum the waster for lowering water level

RECIRCULATE

  By-passes filter for circulating water to pool

CLOSED

  Shut off all flow to filter or pool 

6.Warning

1.  THIS  FILTER  OPERATES  UNDER  HIGH  PRESSURE.  WHEN  ANY  PART  OF  THE 

CIRCULATING  SYSTEM  (e.g.  CLAMP,  PUMP,  FILTER,  VALVES,  ETC.)  IS  SERVICED,  AIR 

CAN ENTER THE SYSTEM AND BECOME PRESSURIZED. PRESSURIZED AIR CAN CAUSE 

THE  LID  OR  VALVE  TO  BE  BLOWN  OFF  WHICH  CAN  RESULT  IN  SEVERE  INJURY, 

DEATH, OR PROPERTY DAMAGE.

2. TURN PUMP OFF BEFORE CHANGING VALVE POSITION.

3.  TO  PREVENT  DAMAGE  TO  THE  PUMP  AND  FOR  PROPER  OPERATION  OF  THE 

SYSTEM, CLEAN PUMP STRAINER AND SKIMMER BASKET REGULARLY.

4. DO NOT UNSCREW SCREWS OF FLANGE CLAMP WHILE PUMP IS RUNNING.

Figure 4

Summary of Contents for Filtration Combo Series

Page 1: ...Filtration Combo Series VC Series USER MANUAL ...

Page 2: ...stic clamps from tank neck b Cap internal pipe with plastic cap to prevent sand from entering it c We recommend filling tank approximately 1 2 way with water to provide a cushion effect when the filter sand is poured in This helps protect the under drain laterals from excessive shock d Carefully pour in correct amount and grade of filter sand Be sure center pipe remains centered in opening Sand su...

Page 3: ... the filter for water leaks and tighten the connections bolts nuts as required 6 Acknowledge the initial pressure gauge reading when the filter is clean It will vary from each pool depending on the pump and general piping system As the filter removes dirt and impurities from the pool water the accumulation in the filter will cause the pressure to rise and flow to diminish When the pressure gauge r...

Page 4: ...rench 23 Motor 12 O Ring Release allairfrom filter and piping system In a flooded suction system water source higher than pump pump will prime itself when suction and discharge valves are opened If pump is not in a flooded suction system unscrew and remove trap cover fill trap and pump with water Clean and inspect Ring re install on trap cover Replace trap cover on trap tum clockwise to tighten co...

Page 5: ...Drain Plug with O ring 1 26 Pressure Gauge with O ring 40psi 1 5 Valve Positions Function Valve Position Function FILTER Normal Filtration and Vacuum BACK WASH Clean Filter by reversing the flow RINSE Use after backwash to flush dirt from valve WASTE By passes filter use to vacuum the waster for lowering water level RECIRCULATE By passes filter for circulating water to pool CLOSED Shut off all flo...

Reviews: