background image

STEAM GENERATOR

Hidro-ST Series

USER MANUAL

Summary of Contents for Hidro-ST Series

Page 1: ...STEAM GENERATOR Hidro ST Series USER MANUAL ...

Page 2: ...HIPMENT AND HANDLING WARNING Only qualified personnel should install and maintain this equipment Unauthorized alteration or improper maintenance of this unit may release the manufacturer from any warranty claims The installation must be in accordance with the instructions in this manual and applicable local plumbing and electrical codes ...

Page 3: ...ST45 3 5 4 5 220V 1 19 4 Hidro ST60 4 2 6 220V 1 28 6 Hidro ST60B 4 2 6 380V 3 9 4 Hidro ST80 6 2 8 380V 3 12 4 Hidro ST90 8 5 9 380V 3 14 4 Hidro ST105 9 3 10 5 380V 3 16 6 Hidro ST120 10 12 380V 3 19 6 Hidro ST150 12 15 380V 3 23 6 Hidro ST180 15 18 380V 3 28 6 All specifications are subject to the latest one changes without prior notice ...

Page 4: ...st set in with strong expansion bolts or equivalent supports C The steam pipe should enter into the steam room and total length less than 6meter and set it at least 300mm above the floor or 150mm far away from the seat D The generator should be mounted in a minimum 0 25m space E The mounting location should minimize the number of bends and elbows in the steam lines F Should not be install in the c...

Page 5: ...nstallation instructions have been correctly followed and then the generator is ready for a trial operation in accordance with operating instructions Water inlet Steam outlet Safety Valve Rinse valve Cable connection Cable connection Water inlet Steam outlet Rinse valve Hidro ST105 Hidro ST120 Hidro ST150 Hidro ST180 Hidro ST30 Hidro ST45 Hidro ST60 Hidro ST60B Hidro ST80 Hidro ST90 Connect the co...

Page 6: ...hould be less than 6m The steam pipe shall slope to the steam bathroom and higher than the position of the steam head so that condensation could drain into the steam room and will not gather in the tube Furthermore the steam pipe should be insulated properly D Install the steam head complying with the instructions The user shall not touch the steam head E The water drainage channel must be opened ...

Page 7: ...ed period the machine will turn off when the counter precipitation 0 The Time setting range is 1 60 minutes Machine default time is 45 minutes 2 Press SET key again the temperature display show two figures of temperature press UP and Down to set your desired temperature The temperature setting range is 35 55 Machine default temperature is 40 3 Press SET key once more to save the above setting And ...

Page 8: ...verheated environment 2 Overheating will present a scald hazard Must be careful while entering the steam bathroom If the steam room is overheated the bather shall get out of the room immediately Regular checking is requested to avoid the leakage or parts damage for the steam head pressure relief valve accessories connections of hermetic parts 3 1 Water rinse Rinse once for each few hours or after ...

Page 9: ...unction 1 Switch off circuit protector 2 Shut off water supply valve 3 Call our maintenance service center There are user serviceable parts in the generator All repairs should be performed by a qualified service person The Trouble Shooting Guide below is for general reference only PROBABLE CAUSES ACTION TO BE TAKEN No steam while controller has been turned ON 1 Steam generator hasn t been connecte...

Page 10: ...outer wall of the steam room can be able to withstand the great temperature changes 5 Voltage of electric source and phase electricity 220V 380V a single phase electricity or three phases electricity Lower voltage causes less steam 6 When installing the steam generator we recommend using a larger size cable than normally used C Announcement The above messages are recommendations only These recomme...

Page 11: ...ch kind of design reduces the space of the steam bathroom 4 Easy cleaning and drainage must be taken into consideration when designing the floor drainage For the consideration of safety the floor must be slipping proof 5 The heights of steam bathroom must be limited to 2 4m or below Heights over 2 4m will cause a high or adequate temperature around the ceiling while the temperature around the floo...

Reviews: