background image

when you option this one, KingKongIII Pro will act as an ESC 

without  Governor  function,  ESC‟s  governor  function  will  be 

taken  over  to  outside  FBL  system  (such  as  Vbar/mini  Vbar/

Skookum/MB/BeastX).  in  this  case,  the  start  type  have  to  be 

set with „soft start‟ and only one of Heli mode parameters can 

be option is: Spool Up Rate.(see the following screenshot). 

 

External Governor

 

     

Kingkong III Pro USER MANUALS                           www.hifei.com

 

There are two Governor Modes in Flight Mode, they are: 

Exter-

nal Governor

 and 

Governor. 

RPM sensor: 

KingKongIII Pro has a built-in RPM sensor to 

provide the rpm signal to the third Flybarless devices such as 

Vbar/mini Vbar / Skookum/BeastX Plus, and the RPM signal 

specification as following: 

 

RPM Signal Voltage: 3.3v 

RPM Signal Duty Cycle : 50% 

Internal Resistance: 510 Ohm 

 

Governor

 

The Governor mode acts as an RPM control. Throttle stick posi-

tion determines the RPM that the motor runs and the controller 

will  attempt  to  hold  that  RPM  regardless  of  load  changes  and 

battery voltage decreasing . Thanks to Active Freewheeling ,the 

motor RPM control could be available as long as the throttle lev-

el  exceed  30%.  In  Governor  Mode,  the‟  brake‟  MUST  always 

disable, „Soft Cutoff‟ and „Soft Start‟ MUST be optioned. 

Note:  we  strong  recommend  to  open  the  Active  Freewheeling 

when Governor is option

 

Spool  Up  Rate 

indicates  the  startup  spool  up  rate,  the  default 

setting is Level 3, higher level numbers 

means to approach the head speed faster. 

 

 

Governor Gain 

The default setting is grade 9, the higher grade 

number means the higher gain. 

 

 

Head  Speed  Change  Rate 

The default setting is standard, this 

setting indicates the change rate between 2 different head speed 

switching (for example, throttle curve switch up from Normal to 

Idle1 or Idle1 to Idle2 ,vice versa). 

The "Head Speed Change Rate" value also determines the speed 

at which the head recovers. 

 

 

AR Recover Time 

is Autorotation Recover Time, it also can be 

understood  as  the  recover  time  from  Autorotation  (TH=0)  to 

Normal  mode.  The  default  setting  is  „Disable‟,  it  indicates  the 

AR is inactived. 

 

10 to 60 Secs can be optioned to determine the recover time that 

Autorotation is actived, for example if you program the AR Re-

cover  Time  to  30  secs,  the  AR  will  be  available  WITHIN  30 

secs, in this period the motor can be ramped up to a preset head 

speed  instead  of  soft  startup,  but  more  than  this time  (  >30  se-

conds) will lead to the motor engaged with soft startup. 

 

 

 

Throttle  Calculator 

is  a  calculator  to  help  you  calculation  the 

throttle curve according to your desired HS, Gear rate and motor 

poles. Please see the following screenshot:

 

 

Page 4

 

Please  read  instructions  of  Flybarless  devices  carefully 

and understand the specifications before connecting ESC 

RPM sensor cable to the devices. 

 

GND

 

RPM Signal

 

Battery

 

FBL/Receiver 

 

Upgrade/RPM 

Throttle 

Summary of Contents for 100A-KIII Pro-6S Lite

Page 1: ... battery black wire Follow the instructions provided with battery connector Connect ESC to motor Suggested to solder quality and corresponding size golden bul let connectors for your motor to the motor wires coming from ESC Swapping any two motor wires connection can change rota tion direction Connect to receiver Connect the receiver lead consisted of brown red and orange small wires with a black ...

Page 2: ...power and slight ly less efficient Option 2 middle 5 20 Recommended for most mo tors Gives a good balance of power and efficiency Option 3 High 15 30 Recommended for most of higher pole count motors Option4 Auto default Recommended for most of all brush less motors Option 5 0 Option 6 2 Option 7 4 Option 8 6 Option 9 8 Option 10 10 Option 11 12 Option 12 14 Option 13 16 Option 14 18 Option 15 20 O...

Page 3: ...h as VBar Skookum MB BeastX etc Option 3 Governor ESC Internal Governor PWM rate Option 1 8 KHz default Recommended for most brushless mo tors Option 2 10KHz Option 3 12KHz Option 4 16 KHz Recommended for very low inductance motors Option 5 20 KHz Option 6 24 KHz Option 7 28 KHz Option 8 32 KHz Active FreeWheeling Option 1 default OFF Option 2 ON helicopter mode than its body diode so much less he...

Page 4: ...n Spool Up Rate indicates the startup spool up rate the default setting is Level 3 higher level numbers means to approach the head speed faster Governor Gain The default setting is grade 9 the higher grade number means the higher gain Head Speed Change Rate The default setting is standard this setting indicates the change rate between 2 different head speed switching for example throttle curve swi...

Page 5: ... pinion or Inc Dec the Desired Head Speed to get the best match results Please carefully check your heli configuration make sure the desired heed speed is under control Furthermore fill out the battery voltage and motor KV can help you find out the ESC power output match with the pre set head speed HiFei recommends for optimum the ESC output to motor about 80 power it ensure the ESC has enough res...

Page 6: ...al size Because big size font would possi bly cause software interface cannot be showed in full Connect ESC to PC Kingkong III Pro USER MANUALS www hifei com HiFei Software V5 0 operation V5 0 tab 2 Parameter setting Click on tab 2 Parameter Setting to get into programming in terface select the options you want to change by down arrow then click on Update to save the setting V5 0 tab 5 Upgrade In ...

Page 7: ...space is filled up it continue logging data indefinitely by overlapping the for mer data and do a cycle Default setting is Not Reverse Sampling rate means the times that data logger samples per second Default setting is 3ps Higher sampling rate will fill up the memory space quickly and thus reduce the logging time when in not reverse record type Sampling Rate Max logging Time Mini running Time Not...

Page 8: ...n device is wrong or occupied by other devices Please open Device manager of My computer to check the right com port number or change the com port number which be occupied to an available port number Then open V5 0 select the right com port number and save it Q It cannot upload data and pops up a box C Program files V5 0 xxx cannot be found A It because ESC run too short time and the logged data c...

Page 9: ... Dongle Connecting the cable to ESC and WiFi dongle Figure 1 Power on the ESC waiting about 30 seconds until the green LED on WIFI dongle blink Option HiFei KIII in the WLAN list of your smart termi nal Open your browser and input the default IP address password as following IP address 192 168 1 16 2015 Password 12345678 Entered into the Home Page Page 9 Reserve Mini USB Reset Attena Home Page Par...

Page 10: ...Dawn Urban Industrial Park Gang An 2 Street Cun Tan Jiang Bei Chongqing 400025 Tel 86 23 6862 1580 6862 6070 Fax 86 23 6862 6070 Note After Updated the The AP name and IP Address Please press Reset button in 1 second and release the red LED will blink in 5 seconds and go to steady light af ter that you have to re power up the WiFi dongle to make the change available ...

Reviews: